Télécharger Imprimer la page

GE Appliances GE30S BLM Serie Manuel D'utilisation page 5

Masquer les pouces Voir aussi pour Appliances GE30S BLM Serie:

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY CONTROLS
The water heater is equipped with a combination
temperature sensor and high limit Energy-Cut-Off
control (ECO) that is located above the upper heating
element in contact with the tank surface. If for any
reason the water temperature becomes excessively
high, the high limit control (ECO) breaks the power
circuit to the heating element. Once the control
opens, it must be reset manually. Resetting of the
high limit control should be done by a qualified service
technician.
CAUTION
The cause of the high temperature
condition must be investigated by a qualified
service technician and corrective action must be
taken before placing the water heater in service
again.
2. With a flat blade screw driver,
lower control housing about
1/8" at top pry location, to allow
rotation of control for opening.
1. Once the Power is turned off at
breaker, remove screw at base
on control housing with Phillps
head screw driver.
READ AND SAVE THESE INSTRUCTIONS
49-6000226 Rev. 7
To reset the temperature-limiting control:
1. Turn off the power to the water heater.
2. Remove the electronic control display and insulation.
Open the electronic control housing by removing
the screw beneath the display using a phillips-head
screwdriver. Push the control display down and
rotate the panel from the top to open and remove
the insulation.
The thermostat protective cover should not be
removed.
3. Press the red RESET button.
4. Replace the insulation, control housing, and screw
before turning on the power to the water heater.
5. Ensure water heater is operating properly after
resetting the ECO.
ECO reset button location
3. Control can now be rotated
downward to access ECO reset
(beneath insulation insert).
5

Publicité

loading