setted successfully. After flashing ,display screen "4" value will return to
current inner water heater temperature. After the smart control energy
saving mode, the knob can not be adjusted.
④
"6" is for frequency display. If number " 1" comes out , it means 1200W(only
one tank is heating ) ; If number "2" comes out , it means 2000W (the two
inner tank has been being heated up ), If number " 3" comes out , it means
smart control energy saving mode, the water temperature is automatically
changed. The appliance works to reduce the electricity energy of the user
consumption, which allows heat loss to be minimized and energy savings to
be maximized. This function is manually activated, The user can press the
MODE button three time at 0 AM local time to start the smart control function
and calibrate the time and hot water usage;
From "5" &"7"(this horizontal strip ) , customer could tell heating status . The
⑤
light "5" will turn on when power is connected. The light "5" will blink , when
smart control energy saving mode is started , According the temperature
setted, the light "7" will be shown in red which means water heater is being
heated. When inner water heater temperature reaches the setted value , light
"7" will turns off , which means water heater enter into warm-keeping status.
"4" could show the current inner water temperature as well as setted
⑥
temperature value.If no person operates on water heater , the value in
display screen " 4" means current temperature value .By spinning knob
"3" , "4" values will vary accordingly ( i.e temperature setting process) ,
when finish temperature setting , "4" values will return back to actual current
inner water heater temperatrue.
Error code for serviceman's use
E2: Dry Ashing---Top up with water and re-heat.
E3: Overheating---Check the heating system or replace it.
E4: Sensor Fault---Check the sensor or replace it.
1.
The supply socket must be earthed reliably. The rated current of the socket
shall not be lower than 10A. The socket and plug shall be kept dry to
prevent electric leakage. Inspect frequently whether the plugs are well
plugged in the socket. Inspect method is as follows: insert the power
supply plug into the socket,after using for half an hour, shut down the unit
and pull the plug out, and inspect the plug in case it scalds your hand. If
tempeature is over 50 ℃, please plug in another socket. to avoid the plug
being damaged, fire or other personnel accidents result from badcontact.
2.
For the places or the wall where the water may splash, the installation
height of the socket shall not be lower than 1.8m.
7