Elpro 42
GB
- 110 V
!
All the possible connections to the control board terminals are also illustrated in the instructions provided with the individual accessories.
NOTE WELL: THE INSTALLATION OF NON FADINI ORIGINAL ACCESSORIES MAY DAMAGE THE PC BOARD. MAKE
!
SURE THAT FREE CONTACTS BE ALWAYS USED FOR THE NO-NC INPUTS. BRIDGE ALL THE NC CONTACTS NOT IN USE.
Dip-Switches
1 = OFF Photocell. No stop in opening
2 = OFF Radio contact 3-7 stop and reverse in opening
3 = OFF Semiautomatic functioning
4 = OFF No pre- ashing before opening
5 = OFF Radio contact 3-7 reverse on each pulsing
6 = OFF
7 = OFF No stroke reversing pulse in opening.
8 = OFF Flasher (contact 11-12) ON in dwell time.
9 = OFF No reclosing after crossing the photocells
10 = OFF No photocell DSA control before any operation
11 = OFF Blank
12 = OFF Blank
Accessory
Photocells:
ZERO.PH Trifo 11 Orbita 57
Keyswitch:
ZERO.EK
ZERO.K
Radio contact:
Receivers:
Astro 43,
Jubi 433,
Siti 63, Birio 868, VIX 53
Main PCB
Receiver
ZERO.DGT
ZERO.SAPE
24 V - max 3 W
pilot light
output:
ELECTRONIC CONTROLLER FOR DARDO 424 GATE OPERATOR
Electrical connections
outer
View from inside property:
inner
F
F 1 2
Outer photocells:
all the NC contacts of the receivers of the outer
+
+
photocells are to be series connected to
terminals 1 and 2: on being engaged, in closing
NC
NC
phase, gate travel is revered to open.
NC
NC
Inner photocells:
all the NC contacts of the receivers of the inner
photocells are to be series connected: on being
engaged, gate travel is stopped in opening,
closing and dwell time untill cleared.
NO and NC contacts to be connected to the
3 4 5 6
respective
button-operated switches.
All possible con gurations are in the
instructions
NC
command accessory.
By any NO connection to these two terminals
3
7
the following is performed, on each pulsing:
- Opening only:
+
Dip 2=ON and Dip 5=OFF
- Travel reversing on each pulsing
Dip 2=OFF and Dip 5=OFF
RADIO
- Step by step operations:
CONTACT
open-stop-close-stop
Dip 2=OFF and Dip 5=ON
Output provided in case a light be required to indicate
8 9
gate status:
Light ON = gate open
-
+
Light OFF = gate closed
Flashing 0,5 s (fast) = gate closing
Flashing 1 s (normal) = gate opening
ON DOUBLE SWINGING GATES
OFF
ON
1 = ON Photocell. Stop in opening
2 = ON Radio contact 3-7 no stop and no reverse in opening
3 = ON Automatic closing after dwell time
4 = ON Fixed pre- asing before gate moving
5 = ON Radio contact 3-7 step by step: open-stop-close-stop
6 = ON Enable braking speed adjustment
7 = ON Stroke reversing pulse for 2 s is enabled in opening
8 = ON Flasher (contact 11-12) OFF in dwell time.
9 = ON Reclosing after crossing the photocells ( Dip 3= ON)
10 = ON Photocell DSA control before any operation
11 = ON Blank
12 = ON Blank
terminals
of
the
key-
attached
to
the
speci c
12
Dip-switch and LED indication
of the various functions
DIP-SWITCH N° 1:
ON: stop in opening and reverse in closing once
obstacle is removed
1
OFF: no stop in opening and reverse in closing
when obstructed
L2 green ON = no obstacle detected,
goes OFF when an obstacle is detected
L4 red OFF = no OPEN contact,
it goes ON whenever an open pulse is given
or
L5 red OFF = no CLOSE contact,
it goes ON whenever a close pulse is given
L6 green ON = STOP contact closed,
it goes OFF whenever a stop pulse is given
DIP-SWITCHES N° 2 AND 5 (do NOT set both of
them to ON at the same time):
ON: no stop and no reverse in opening
2
OFF: stop and reverse in opening on pulsing
ON: step by step with stop in between
5
OFF: gate travel reverse on radio pulsing
L7 red OFF = no RADIO contact,
it goes ON whenever a radio pulse is given