Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
FT120C/FT130C

Air Filters

Clean the air filters. Remove the filter end cover [c], wash the air intake filter [b] using a light
detergent, and dry it thoroughly before re-installing. Replace the air delivery filter [a] once a
year.
Ignition Electrodes
Clean, adjust and, if necessary, replace the ignition electrodes.
Compressor Pressure Adjustment
The compressor pressure is factory-set and must be checked and adjusted by qualified
technicians only. Tampering with the unit may be dangerous.
Remove the pressure gauge cap [a]. Connect a pressure gauge on the pressure measuring port
on the rear guard. Start the device and read the air pressure value. If necessary, adjust the
pressure to the correct value turning the adjusting screw (the air vent hole [b]) clockwise to
increase, or anticlockwise to decrease the pressure.
pressure gauge cap
air vent hole
a
b
Electrical
Inspect all cables, electrical parts and connections.
V. 05 – 23/04/2020