Stove Will Not Feed Pellets, But Fuel Feed Light Comes On As Designed
Possible Causes
High limit switch has tripped or is
1.
defective.
Bad Auger Motor.
2.
Auger Jam.
3.
Loose wire or connector.
4.
Bad control board.
5.
Possible Causes
The convection blower is overheating
1.
and tripping the internal temperature
shutoff.
The stove is being left on the highest
2.
setting for extended periods of time.
Fuel other than wood pellets is being
3.
burned in the stove.
Power surge or brown out situation.
4.
High limit switch is malfunctioning.
5.
22
All manuals and user guides at all-guides.com
Trouble Shooting Guide
Possible Remedies: (Unplug stove first when possible)
Wait for the stove to cool for about 30 - 45 minutes. Locate
the High Limit thermodisc and press the reset button on the
back of it. If the heater will not restart, check the thermodisc
to see if it's bad. To test if the thermodisc is bad, you can
bypass it as described previously for the POF thermodisc.
Remove the auger motor from the auger shaft and try to
run the unit. If the motor will turn the shaft is jammed on
something. If the motor will not turn, the motor is bad.
Start by emptying the hopper.
motor by removing the auger pin. Remove the auger shaft
inspection plate in the hopper so that you can see the
auger shaft. Gently lift the auger shaft straight up so that the
end of the auger shaft comes up out of the bottom auger
bushing. Next, remove the two nuts that hold the top auger
biscuit in. Then rotate the bottom end of the auger shaft up
towards you until you can lift the shaft out of the stove. After
you have removed the shaft, inspect it for bent flights, burrs,
or broken welds. Remove any foreign material that might
have caused the jam. Also, check the auger tube for signs
of damage such as burrs, rough spots, or grooves cut into
the metal that could have caused a jam.
Check all wires and connectors that connector to the auger
motor, high limit switch, and the Molex connector.
If the fuse is good, the wires and connectors check out
good, and the high limit switch did not trip, test for power
going to the auger motor. If there is not a full current going
to the auger motor when the fuel feed light is on, you have
a bad control board.
High Limit Switch Keeps Tripping
Possible Remedies: (Unplug stove first when possible)
Clean any dust off of the windings and fan blades. If oiling
the blower does not help, the blower may be bad.
If operating the heater on the highest heat setting, the room
temperature could increase enough and lead to potential
overheating situations. If this happens, try operating at a
lower heat setting.
This pellet stove is designed and tested to use wood pellets.
Check for signs of fuel other than wood pellets. No other
types of fuel have been approved for this pellet stove. If
there are signs of other types of fuel being used, stop using
them immediately.
A power surge, spike, or voltage drop could cause the high
limit switch to trip. Check to see if a surge protector is being
used on the stove. If not, recommend one to the consumer.
If the other items check out OK, replace the high limit switch.
Then remove the auger