MVA 500 G/W SHUT-OFF VALVE
The shut-off valve is simple to operate, with 90° turn and click effect. The open/shut position is clearly rec-
ognizable: handwheel parallel to gas line – valve open. Handwheel at right angles to gas line – valve closed.
MVR 500 G/W METERING VALVE
Fine dosing metering valve with good control characteristics at high and low flow levels. (at maximum 10
knob turns open to closed). Please keep attention: only shut-off valves guarantee the secure interruption of
gas flow.
4.7. ACCESSORIES
An extensive range of accessories is available for the 500 series. This includes screwed fittings, hose noz-
zles, contact pressure gauges and flashback arresters. For further information please contact the manufac-
turer. The assembly and installation instructions for these components must be observed.
5 .
IDENTIFICATION
The rating plates provide the following information: Manufacturer, date of manufacture, type designation,
permissible inlet pressure (pein), device-specific outlet pressure range (paus), materials of regulator body and
seal gasket, safety information, and gas type symbol. The serial number is provided as a device-specific iden-
tification on a separate plate in bar code 128 and in type.
Please use only pressure device suitable to gas type and
pressure pre-descriped on the rating plate and labelling.
Thread of danger to life and health of persons and/or
damage of pressure device.
Typ: EMD 400-01
Mat: Ms / Ni / PVDF
Pin:
Pout: 0,5 - 10 bar
6 .
INSTALLATION
6.1. CYLINDER PRESSURE REGULATORS
The threads of the cylinder valve and the union nut must
be in impeccable condition.
Always use new gaskets. Gaskets must not be deformed
and must show no traces of dirt or metal turnings.
Attention: Do not use spanner extensions because they
may destroy the thread and the gasket. This can lead to
leaks or to complete and uncontrolled loss of the gas
supply.
When connecting or changing cylinders containing toxic
or corrosive gases, appropriate personal protection
measures must be taken (respiratory protection, eye
protection and protective clothing). Observe the MAK
values (maximum workplace concentration value; see
Technical norms for dangerous substances, TGRS 900)
and have the correct respiratory protection filters at
hand..
Before connection, check the rating plate to determine whether the equipment is suitable for the intended
use (type of gas, pressure, etc. see section 5).
PREPARATION
Use only cylinder connections appropriate for the type of gases used according to DIN 477.
CONNECTION TO THE CYLINDER
First screw the union nut onto the cylinder by hand. Pay attention to right- and left-handed threads! Align
1.
the regulator. Do not tilt it when setting it on!
Tighten the union joint with the appropriate open-end spanner. Do not use spanner extensions!
2.
Attention!
Pressure device.
Service only by
40 bar
autorised persons
He
Fig. 7: Cylinder pressure regulator to connect to
gas cylinder to connect to gas cylinder
Fig. 8: Assembly of pressure regulator
to the gas cylinder
19/44
EN
Seal