rOOF MOUnT
For use with Models ICBPW3048, ICBPW3648, ICBPW448, ICBPW4848, ICBPW5448,
ICBPW6048, ICBPW6648, ICBPW3078,
ICBPW3678, ICBPW478, ICBPW4878,
ICBPW5478, ICBPW6078, ICBPW6678,
ICBPL34, ICBPL46, ICBPL5
prepare the roof
18"
1¼" dia. hole
REMOVE SHINGLES
12
/
"
11
16
Pilot Hole
(centered
between rafters)
12
/
5
8
From inside the attic space:
1
Drill a PiLOT HOLE up through the roof, centered between
rOOF raFTErS.
From outside - on the roof:
2
Measure and mark the 21" x 20½" rectangle. Cut and
remove only the shingles inside this rectangle.
3
Measure and mark the 11" DiaMETEr HOLE and the 1¼"
DiaMETEr HOLE. Cut these holes all the way through
the roof.
For flat roof installations:
4
Build a curb that will mount the blower at a minimum pitch
of 2/12. Discharge end of the blower should be pointed
away from prevailing winds.
inSTaLLaTiOn
1"
11" dia.
hole
"
21"
2 "
install the Ventilator
5
Remove 10 COVEr SCrEwS and lift off ventilator cover.
6
Remove roofing nails from top 2/3 of shingles around cut-
out area.
7
Feed the electric power cable (supplied with ventilator)
through the 1¼" DiaMETEr HOLE in roof.
8
Slide ventilator's FLaSHing SHEET up and under loosened
shingles until ventilator's discharge collar fits into 11"
diameter hole.
9
Use 6 screws (provided) to attach ventilator to roof. DriLL
6 MOUnTing HOLES inside ventilator, as necessary.
10
Seal screw heads, loosened shingles, and edges of
flashing sheet with a good grade of roofing cement.
11
Check for free movement of spring-loaded damper and
re-install ventilator cover.
20½"
10 Cover
10 Cover
Screws
Screws
Flashing
Sheet
attach power cords to hood
12
The ventilator is prewired with 12 feet of H05VV-F
3G1 power cable. Run ventilator cable to range hood's
7 "
electrical wiring box.
13
Secure cable to range hood with a strain relief (included
in parts bag). Make wiring connections per instructions
provided with your Wolf range hood.
14
Install the separate power cord and strain relief (included
in parts bag) to the range hood. Refer to instructions
provided with your Wolf range hood.
15
Turn on power and check for proper operation of
ventilator.
MODEL 812309
Damper
Bird Screen
OUTSIDE - ROOF VIEW
OUTSIDE - ROOF VIEW
Page
Drill 6
Mounting
Holes
Remove
roofing
nails from
top 2/3 of
shingles.