Amplifier Control System
Display mode
You can set up the display items as follows:
1
Enter Menu mode
Press the [MENU] button.
"VOLT"/"CURR"/"TEMP"/"FAN" is displayed.
2
Select a display item
Press the [2] or [3] button.
The display items are switched in the following sequence.
Display
Information
"VOLT"
Indicates the source voltage (V).
"CURR"
Indicates the current consumption (A).
"TEMP"
Indicates the internal temperature (°F/°C).
"FAN"
Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF".
3
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is
displayed.
Separate Amp Control
You can control sounds using the Amplifier Control function of the unit.
1
Enter Menu mode
Press the [MENU] button.
2
Select the Menu item
Press the [MENU] button.
The setup items are displayed approximately 1 second first, then the set
values are displayed.
3
Adjust the Menu item
Press the [2] or [3] button.
The setup items and set values are switched as follows.
Display
Range
Adjustment Item
"VOLT"/"CURR"/"TEMP"/"FAN"
For the operation method refer to <Display mode>
"BASS"
60/80/100/200 (Hz)
Bass Center Frequency
"BA G"
B–15 — B+15 (dB)
Bass level
"BA Q"
Q1.00/Q1.25/Q1.50/Q2.00
Bass Q Factor
When the bass extend is set to ON, low frequency response is
"EXT"
ON/OFF
extended by 20%.
"VOL"
–20 — 0 (dB)
Volume offset
FAHR (Fahrenheit) or
The Fahrenheit or Centigrade temperature unit can be selected
"TEMP"
CELS (Centigrade)
for the Display mode.
"DEFA"
For the operation method refer to <Default>
"AMP"
0 — 7
The ID Number you have assigned is displayed.
6
English
FAN
VOLT
TEMP
CURR
2
3
4
(MIN)5
SENSITIVITY(V)
LPF OPERATION
0
200 Hz
AMP CONT
150 Hz
ON
-4
100 Hz
-8
70 Hz
50 Hz
-12
-16
-20
OFF
30
40
50 60
100
200
300 400
1K
(Hz)
4
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When you hold down the [3] button 3 or more seconds during ID number
display ("AMP"), message "MEMO" is displayed and you can register the values
you have set with the Amplifier Control. To call the Amplifier Control's values,
hold down the [2] button 3 or more seconds during ID number display
("AMP"). Then, you can recall the value when message "LOAD" is displayed.
Default
Resets all values you have set to the initial (default) values.
1
Enter Menu mode
Press the [MENU] button.
2
Select Default mode
Press the [MENU] button.
Select the "DEFA" display.
3
Resets the value to its default
Press the [3] button for at least 2 seconds.
Message "----" is displayed, and the value is initialized.
4
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
Volume offset value can not be initialized.
Display Demonstration
The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.
Press the [MENU] button for at least 2 seconds.
The indicator flashes in the Demonstration mode.
Canceling the Demonstration mode
Press any button to cancel the Demonstration mode.
1
150
100
0.5
70
0.2(MAX)
50
200
40
200
INPUT
LPF
B.R.F
FREQUENCY(Hz)
FREQUENCY(Hz)
PHASE
BRF
ISF
ISF FREQUENCY
180°
-12dB
ON
25Hz
-6dB
OFF
OFF
15Hz
Indicator
MENU
2 / 3