Télécharger Imprimer la page

Astralpool EVOLine Serie Manuel D'instructions page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Technical Specification
Model
Codes
EVOLine 6
66069-R32
EVOLine 10
66070-R32
EVOLine 13
66071-R32
EVOLine 15
66072-R32
EVOLine 17M
67405-R32
EVOLine 20M
66073M-R32
EVOLine 20T
66073-R32
EVOLine 25M
66074M-MOD
EVOLine 25T
66074-R32
EVOLine 35T
66075-R32
For water pump connection, please externally equip suitable A/C contactor (not included in heatpump)
1.4 First time start-up :
Note- In order for the unit to heat the pool (or spa), the filter pump must be running so that the
water can circulate through the heat pump. Without this circulation, the heat pump will not
start.
When all connections have been made and checked, the following steps should be followed:
1). Turn on the filter pump. Check for leaks
2). Turn on the electrical power supply to the unit, then press the ON/OFF key on the electronic
control
panel. The unit should start when the time delay period has elapsed.
3). When the unit has been running for a couple of minutes, check if the air leaving the unit is cooler
than the ambient temp.
4). Check the performance of the flow switch as follows: with the unit running turn the filter pump off.
The unit should also switch off automaticall .
5). The unit and the filter pump should run 24 hours a day until the desired pool water temperature has
been reached. Once the set temperature is reached, the unit will switch itself off. As long as the filter
pump is running, the unit will restart automatically when the temperature of the pool water drops more
than 1°C below the set temperature.
Depending on the starting temperature of the pool water and the air temperature, it can take several
days for the water to reach the desired temperature. Covering the pool can drastically reduced this
period.
Water flow switch—the unit is equipped with a flow switch that is switched on when enough water
has flowed through the unit and that is switched off when the water flow becomes too
the filter pump is switched off)
Time delay— the unit is equipped with a built-in 3-minute start delay included to protect electrical
components and contacts. After this time delay, the unit will automatically be restarted. Even a brief
interruption of the power supply will activate the start delay and prevent the unit from starting imme-
diately. Additional interruptions of the power supply during the delay period will have no effect on the
3-minute countdown.
Voltage (volt)
Current (A)
220-240
220-240
220-240
220-240
220-240
220-240
13.5
380-400
220-240
16.8
380-400
380-400
10.1
11
Cable diameter (mm
for max length 20m
4.1
2 x 1.5mm
+Ground
2
6.2
2 x 2.5mm
+Ground
2
8.9
2 x 2.5mm
+Ground
2
9.7
2 x 2.5mm² +Ground
11
2 x 2.5mm² +Ground
2 x 4.0mm² +Ground
5.1
4 x 2.5mm
+Ground
2
2 x 4.0mm² +Ground
5.6
4 x 2.5mm
+Ground
2
4 x 4.0mm
+Ground
2
EN
)
2
. (E.g. When

Publicité

loading