1.2 Pool system set up
Heat Pump
Water processor
Side connection valve
Outlet
Inlet
Power cable inlet
Condensed water draining pipe
Water pump
Filter
Pool water inlet
Draining nozzle Discharge water to pool
1.3 Warning :
Important—Although the heat pump is electrically isolated from the rest of the unit, this only
prevents the passage of electricity to or from the pool water. Grounding the unit is still required to
protect yourself from short circuits inside the unit. Make for adequate ground connection.
Electrical protection: by circuit breaker (D curve, rating to be defined according to the table below,
with a suitable dedicated residual-current device (circuit breaker or switch).
Additional protection may be required during installation to guarantee the overvoltage category II.
The power supply must correspond to the voltage indicated on the appliance's information plate.
Check if the electrical mains voltage corresponds with the operating voltage of the heat pump prior to
hooking up the unit.
230V / 1ph / 50Hz
380 - 400V / 3ph / 50Hz