Test voltage
Working voltage
(basic insulation)
EMC
3)
Surge withstand
Ambient temperature
Power supply
Design
Ingress protection
Weight
Higher load on the voltage output on request
1)
Average TC in specified operating temperature range -10 °C to +60 °C
2)
Slight deviations are possible while there is interference.
3)
22
3.25 kV AC input against output against power supply
600 V with overvoltage category II and pollution degree 2
according to EN 61010-1
For applications with high working voltages, take measures
to prevent accidental contact and make sure that there is
sufficient distance or insulation between adjacent devices.
Product family standard: EN 61326
5 kV, 1.2/50 µs, according to IEC 255-4
Operation
Transport and storage
230 V AC ± 10 %, 1 W, 48 to 62 Hz, 2 VA
(overvoltage category II)
Option 336: 24 V AC/DC ± 10 %, 1 W
AC: 48 to 62 Hz, 2 VA
Modular housing type F1, with screw terminals
See dimension drawings for dimensions
IP 20
Approx. 150 g
-10 to +60 °C
-20 to +85 °C