Settings
After power on, digital display will self-check from 00-99 with buzzer sound.
If indicator LED lights on, and the buzzer stops, it means the system is normal
working condition.
Basic operation
Press and hold the FUN button until PO appears on the screen. You have now
entered the settings menu. Use the INC + and DEC + buttons to navigate
the menu or to increase and decrease numeric values. Press the FUN button
to save the settings. You will hear a confirmation beep. After saving the data
on the screen, the menu where you made the lastest settings will be displayed.
To go to the next menu, press the INC + and DEC + buttons to navigate
through the menu and the FUN button to enter the desired menu.
After you set the value of P0 and pressed the FUN button to save it, P0 will
keep showing on the screen. If you want to set P1, press the INC + button, P1
will appear on the screen and then FUN to enter the P1 settings.
If you want to exit the menu, press the LEARN button.
1. Smooth start time setting (P0)
P0 appears on the digital display. Options available between 0 and 6 sec. The
value 0 disables this function. Use the INC + button to increase the value by
one unit and DEC- to decrease the value. Press FUN to save the data. The
factory value is 2 seconds.
2. Setting the level of stall force
P1 on the display, the device is set to low speed stop force for Motor1.
»
There are optional values from 0 to 20; After choosing the value, press
the FUN button to save the data. (factory setting is 6).
P2 on the display, the device is set to high speed stop force for Motor1.
»
There are optional values from 0 to 20; After choosing the value, press
the FUN button to save the data. (factory setting is 10).
P3 on the display, the device is set to low speed stop force for Motor2,
»
optional values from 0 to 20. After choosing the value, press the FUN
button to save the data (factory setting is 6).