Operation
Attention!
Observe the following instructions to prevent the risk of
injuries and damage to the device:
1. Never lay down the device on its side in its hot operative
2. Never remove adhesive residues from the melting
3. Never loosen cooled off hot-melt adhesive sticks by
4. You should never pull the cold glue stick out of the
5. Never use the trigger (2) with force.
6. Comply with the processing data sheet of the hot melt
7. When working upside down, watch out for possible drips
8. Always disconnect the mains plug before carrying out
4.1
Initial operation
1. Plug the mains plug (3) into a protective earth conductor outlet.
2. Switch on the device at the on/off switch (4).
The digital display (8) lights up in blue. After the working temperature has
been reached and a waiting time has elapsed, the display colour changes
to green. The device is now ready for operation. The digital display shows
the actual temperature of the applicator and the adjusted temperature
when the Set key (7) is pressed. The device heats up immediately.
3. Liquid adhesive may emerge from the nozzle if the adhesive candle is al-
ready inserted. Therefore, place the device on a suitable surface. Allow the
device to heat up for approx. 6 - 8 minutes (depending on adhesive type).
4. Insert the hot melt adhesive candle through the opening on the back of the
device.
HB326XM_220208.indd 18
state. This could cause the hot melt adhesive to leak
unchecked. Danger of burns!
chamber by force (e.g. with a scraper or screwdriver).
This could damage the interior lining of the melting
chamber.
force (e.g. with tongs).
device. This can cause damage to the transport mecha-
nism.
adhesive (protection against processing errors).
to avoid burns to personnel or work items.
any work on the device (maintenance, cleaning).
18