Télécharger Imprimer la page

Kärcher IVR 100/30 Pp Sc Mode D'emploi page 9

Publicité

Les langues disponibles

Les langues disponibles

2. Remove the filter unit from the de-
vice using the handles and turn it
over.
3. Remove the screws and remove the
cleaning fixture.
4. Loosen the clamping ring screw
connection.
5. Remove the pocket filter.
6. Fit the new pocket filter.
During installation, take care to en-
sure that the lug on the filter insert
engages the shaft.
Illustration H
Error
Reduced suction
performance
Cause
The suction hose or the suc-
tion nozzle is blocked.
The installed compressed air
filter / controller is blocked or
faulty.
The suction hose is leaky.
The suction hose is not seat-
ed properly in the suction fit-
ting.
The collection container is
full.
The surface filter is contami-
nated.
The seal between the drive
unit and the collection con-
tainer is faulty.
The compressed air filter in
the connection sleeve is
contaminated.
7. Fit the clamping ring and tighten.
8. Fit the cleaning fixture and tighten.
Troubleshooting guide
The malfunctions listed can be rectified
by the user. Ringler Customer Service
should be contacted in the event of any
other malfunctions: Tel. +49 (0) 7171
94888 0.
Rectification
 Remove the blockage.
 Remove the blockage and/or
replace the compressed air fil-
ter/controller.
 Replace the suction hose.
 Fit the suction hose correctly.
 Empty the collection contain-
er.
 Clean or replace the filter.
 Replace the seal.
 Clean or replace the com-
pressed air filter.
English
9

Publicité

loading

Ce manuel est également adapté pour:

Ivr 100/30 pp sc hepa