JnstaJlationinstructions
D WINDOW REQUIREMENTS
• These instructions are for a standard double-hung
window. You will need to modify them for other types
of windows.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
• Follow the dimensions in the table and illustration
for your model.
t_
19 1/4;'
_--------29"
- 41 "
(With accordion panels)
1
D STORMWINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it
from draining properly.
To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH:2"
LENGTH:Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2" higher
than the top of the storm window frame or the vinyl
frame.
Attach securely with nails or screws provided by the
installer.
1/2" higher
than storm
window
frame
Storm window
frame
1/2" higher
than vinyl frame
_
_ (on some windows
_
Wood
r_
Vinyl frame
I
D PREPARETHE AIR CONDITIONER
[]
Remove the two control knobs.
r_
Pull down the front panel and remove the filter.
Remove the front panel by lifting up at an
angle.
[]
Remove
the four front
screws.
Save them
for reinstalling
the front
housing.
i i iiiii!li,iililtiill!,!iiilli,l
Grasp
the lower
corners
of the grille
while
pressing
in on the case sides with
your
finger
tips. Pull out to release
and lift it up.
NOTE:
Do not pull the bottom
edge
toward
you more
than 3" or you may
damage
the tabs of the grille.