TROUBLESHOOTING
Fault
Light on, but fan does
not work
Both light and fan do
not work
Serious Vibration
of the unit
Suction per-formance
not good
HINTS ON DISPOSAL
Manufacturer
Intax Trading SRL
14B Ion Creanga Str., 075100, Otopeni, Ilfov, Romania
office@intaxtrading.com
www.intaxtrading.com
Cause
The fan blade is jammed.
The motor is damaged.
light bulb burn.
Power cord looses.
The fan blade is damaged.
The fan motor is
not fixed tightly.
The unit is not hung
pro-perly on the
bracket.
Too long distance
between the unit and
the cooking plane
According to the European waste regulation 2012/19/EU this
symbol on the product or on its packaging indicates that this
product may not be treated as household waste. Instead it
should be taken to the appropriate collection point for the
recycling of electrical and electronic equipment. By ensuring this
product is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste
handling of this product. For more detailled information about
recycling of this product, please contact your local council or
your household waste disposal service.
Solution
Switch of the unit and
repair by qualified
service personnel only.
Replace the bulb
with correct rating.
Plug in to the power
supply again.
Switch of the unit and
repair by qualified
service personnel only.
Take down the unit and
check whether the bracket
is in proper location.
Readjust the
distance to 65-75cm