3.2. Setup menu
The setup menu can be entered by pressing "SETUP" during three seconds.
Scrolling text
   
   
  
  
  
  
  
  
  
  
  
   
    
   
    
    
  
   
   
  
   
   
   
    
 
  
   
   
  
   
  
 
   
  
  
  
  
  
After entering the setup menu, the user can scroll through the menu with the up/down keys.
With select a menu item is entered and the present value is shown. With the up/down keys the user can scroll through the available
modes or increase/decrease the value.
By pressing select again the value/item is set.
Pressing setup shortly will return to the setup menu.
When setup is completed, exit the menu by pressing "SETUP" again three seconds.
Icons
Segments
.-.-.
.-.-.
.-.-.
.-.-.
.
.-.-.
.-.-.
.-.-.
.-.-.

.-.-.
.-.-.
.-.-.
.-.-.
.-.-.

.-.-.

,,

.



9
Units
Function or parameter
On/off switch
,
A
Maximum charge current
.-.
V
System voltage (read-only)

Type
Charge algorithm
,-
V
Absorption voltage
V
Float voltage
V
Storage voltage
V
Equalization voltage
Automatic equalization
,
Manual equalization
,
Relay function
-
V
Low battery voltage alarm set
V
Low battery voltage alarm clear
V
High battery voltage alarm set
V
High battery voltage alarm
clear
Relay minimum closed time
-
(minutes)
°C mV
Battery temperature
compensation per cell
h
Bulk time protection
,
h
Absorption time
Storage mode
,
h
Maximum float time
h
Repeated absorption time
Day
Repeated absorption interval
A
Low temperature charge
.-.
current
Watch function (start-up in
, 
storage if battery voltage >13 V
BMS Present
,
V
Power supply voltage
A
Input current limit
.-.
The intensity of the backlight
--
Backlight automatic turn off
after 60s
Text scroll speed
--
Buzzer
,
VE.Can device instance
-
Software version
System reset to default
settings
History data reset
Lock settings
,
Temperature unit °C/°F
,

Publicité