Overload capacity:
Output signal A
Output signal (I
):
A
Transformation ratio:
Residual ripple in
output current:
Time constant:
Output load voltage:
Accuracy data
Reference value:
Deviation from specified
characteristic under
reference conditions:
Reference conditions:
Ambient temperature
Input current I
E
External load R
ext
Additional error:
Dependence on
output load
Temperature influence
Installation data
Mechanical design:
Mounting versions:

5. Type overview

Description
Standard version
Improved climatic rating
Intrinsically safe input
Intrinsically safe output
12
≤ 50 mA continuous
Load-independent DC current
1 : 1
≤ 0.5% (7 kHz)
Approx. 100 ms
U
= U
– U
(Fig. 2)
A
E
V
20 mA
Max. ± 0.1%
23 °C ± 1 K
0...20 mA
250 Ω
< + 0.1% / 100 Ω
if R
< 250 Ω
ext
< – 0.1% / 100 Ω
> 250 Ω
if R
ext
< 0.1% / 10 K
for + 10 ≤ t ≤ + 40 °C
< 0.2% / 10 K
for – 25 ≤ t ≤ + 10 °C and
for +40 ≤ t ≤ +55 °C
Housing type N in plastic for
rail or wall mounting. (Dimen-
sions see "8. Dimensional dra-
wings")
For snap mounting on G-type
rail or cap-type rail (see "8.
Dimensional drawings")
Mounting position:
Electrical connections:
Weight:
Regulations
Electromagnetic
compatibility:
Intrinsically safe:
Max. surge voltage:
Electrical design:
Protection:
Test voltage:
Environmental conditions
Operating temperature:
Storage temperature:
Relative humidity
of annual mean:
Altitude:
Indoor use statement!
Type
84-2I1-10
84-2I1-10
84-2I1-11
84-2I1-12
Any
Screw terminals with indirect
wire pressure, suitable for,
max. 2 ×1.5 mm
or
2
1×2.5 mm
2
Approx. 100 g
The standards DIN EN 50 081-2
and DIN EN 50 082-2 are obser-
ved
Acc. to EN 50 020: 1994
5 kV, 1.2/50 µs surge withstand
test
IEC 255.4 and Surge withstand
test, as per IEEE-Std. 472-
1975.
Common-mode and differen-
tial-mode between any two
terminals
Acc. to EN 61 010
Housing IP 40 acc. to
EN 60 529
Terminals IP 20
4 kV, 50 Hz, 1 min.
– 25 to + 55 °C
for standard version
– 20 to + 40 °C
for Ex versions
– 40 to + 70 °C
≤ 75% standard climatic
rating
≤ 90% improved climatic
rating
2000 m max.
Article Number
154 253
154 261
154 279
154 287