IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
W10201609C

Publicité

loading

Sommaire des Matières pour Jenn-Air JXDR7301VS

  • Page 1 RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM SYSTÈME D’EXTRACTION RÉTRACTABLE (CLAPET) À ® ASPIRATION PAR LE BAS JENN-AIR 30" ET 36" (76,2 CM ET 91,4 CM) Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-688-1100 or visit our website at www.jennair.com.
  • Page 2 TABLE OF CONTENTS TABLE DES MATIÈRES VENT SYSTEM SAFETY..............3 SÉCURITÉ DU SYSTÈME DE VENTILATION ......22 INSTALLATION REQUIREMENTS ..........5 EXIGENCES D'INSTALLATION ...........24 Tools and Parts ................5 Outillage et pièces..............24 Location Requirements ..............5 Exigences d'emplacement............24 Electrical Requirements ...............7 Spécifications électriques ............26 Venting Requirements..............7 Exigences concernant l'évacuation ...........26 INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION...
  • Page 3 VENT SYSTEM SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may Use this unit only in the manner intended by the ignite.
  • Page 5 INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. NOTE: Downdraft vent is installed directly behind the cooktop. Read and follow the instructions provided with any tools listed Install the downdraft vent first, then install the cooktop. here.
  • Page 6 Product Dimensions Countertop Cutout Dimensions IMPORTANT: Countertops with a bull-nosed front edge are not Interior-mounted blower motor model recommended for these installations. Some models require a countertop deeper than 25" Top trim widths: (63.5 cm); see the following Countertop Cutout Dimensions 30¹⁄₄"...
  • Page 7 Electrical Requirements IMPORTANT: Observe all governing codes and ordinances. Save The downdraft vent must be connected with copper wire Installation Instructions for electrical inspector’s use. only. It is the customer’s responsibility to contact a qualified electrical The downdraft vent should be connected directly to the installer, and to ensure that the electrical installation is adequate circuit breaker (or fused disconnect) box through flexible and in conformance with National Electrical Code, ANSI/NFPA 70...
  • Page 8 INSTALLATION INSTRUCTIONS INTERIOR-MOUNTED VENT MOTOR Venting Methods - Interior Mounted Vent Motor Only Island Location Determine which venting method is best for your application. Vent system can terminate through either the wall or floor. Vent system installed under a concrete slab using PVC sewer pipe.
  • Page 9 To calculate the length of the system you need, add the The following example falls within the maximum vent length of equivalent feet (meters) for each vent piece used in the system. 35 ft (8.9 m). Vent Piece 6" (15.2 cm) Round 2 - 90°...
  • Page 10 5. Attach the left and right side end caps to the downdraft vent. Determine which direction is best for your installation. Place the end cap upon the overcounter support, slide the tab into the slot and snap into place over the the plastic tabs. When installed in a cabinet, vent system can exhaust through the bottom, right, left or rear of the cabinet.
  • Page 11 4. Place the bottom tab of the blower box into the bottom 2. Lift up the blower box from the bottom mounting channel and mounting channel. set aside. A. Blower box B. Bottom mounting channel A. Blower box B. Bottom mounting channel 3.
  • Page 12 6. Install blower motor and mounting bracket assembly to the 9. Replace the vent box over the blower motor. bracket just below the downdraft tower motor. The blower exhaust opening should fit through the hole in the large cover plate on the opposite side of the vent chamber where the small cover plate was removed.
  • Page 13 Rear Mounting - Blower Motor NOTE: Optional blower motor mounting position (opposite side). 2. Lift up the blower box from the bottom mounting channel. The blower motor box assembly can also be moved to the opposite side (rear) of the vent box. A.
  • Page 14 5. Lift up the panel from the bottom mounting channel. 8. Tilt blower box top tab so it is flush with the vent box panel and position it under the top mounting bracket. Slide bracket into the “Z” slots and tighten the 2 hex/slotted head screws to secure.
  • Page 15 Complete Installation Make Electrical Connections 1. Attach backdraft damper over 6" vent extension. Secure with WARNING vent clamp. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1.
  • Page 16 4. Connect the 2 white wires together using UL listed wire connectors. Check Operation 1. Push and hold the button on the top of the downdraft vent for a few seconds. The retractable section of the downdraft vent will rise, and the blower will start. Position the top trim over the retractable section and snap trim into place.
  • Page 17 VENT SYSTEM USE The retractable downdraft vent system is designed to remove 2. Slide the control slider on the right-hand side of the smoke, cooking vapors and odors from the cooktop area. downdraft vent to adjust the blower motor speed. For best results, the vent should be operating before cooking When cooking is complete: is started.
  • Page 18 WIRING DIAGRAM SPEED PUSH BUTTON REGULATION UP/DOWN 5x20 800 mA Time Delay FUSE GEAR MOTOR FILTER SWITCHES FLAT CABLE TOROIDAL TRANSFORMER VDR1 ELDD SIDE INSERT CABLES INTERNAL BLOWER LINE IN 120 Vac 60 Hz...
  • Page 19 Call the dealer from whom your appliance was purchased, or call If you need to order replacement parts, we recommend that you Jenn-Air at 1-800-807-6777 to locate an authorized service use only factory specified parts. Factory specified parts will fit company.
  • Page 20 Jenn-Air brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter “Jenn-Air”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Jenn-Air designated service company. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased.
  • Page 21 Notes...
  • Page 22 SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 23 IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance.
  • Page 24 EXIGENCES D'INSTALLATION Outillage et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant de commencer REMARQUE : Le système d’extraction par le bas est installé l'installation. Lire et observer les instructions fournies avec les directement derrière la table de cuisson. Installer d'abord le outils de cette liste.
  • Page 25 Dimensions du produit Plan de travail - Dimensions des ouvertures à découper IMPORTANT : Les plans de travail avec bords arrondis ne sont Modèle avec ventilateur monté à l'intérieur pas recommandés pour ces installations. Garniture supérieure : 30¹⁄₄" (76,8 cm) pour système Pour l'installation avec un système d’extraction, il faut que la d’extraction de 30"...
  • Page 26 Spécifications électriques IMPORTANT : Observer les dispositions de tous les codes et En cas d'incertitude quant à la qualité de la liaison à la terre règlements en vigueur. Conserver les instructions d'installation de l'appareil, consulter un électricien qualifié. pour consultation par l'inspecteur des installations électriques. Le système d’extraction par le bas doit être raccordé...
  • Page 27 INSTRUCTIONS D'INSTALLATION VENTILATEUR MONTÉ À L'INTÉRIEUR Méthodes d'extraction - Seulement pour un ventilateur monté à l'intérieur Déterminer quelle méthode d’extraction est la plus appropriée. Configuration de cuisine en îlot La sortie à l'extérieur du système d’extraction peut se faire à Système d’extraction installé...
  • Page 28 Pour calculer la longueur effective du système d’extraction nécessaire, additionner les longueurs équivalentes (pieds/mètres) Installation du système d’extraction de tous les composants utilisés dans le système. Composant Système de diamètre 6" (15,2 cm) AVERTISSEMENT coude à 45° 2,5 pi Risque du poids excessif (0,8 m) Utiliser deux ou plus de personnes pour déplacer et installer le système d’extraction.
  • Page 29 6. Fixer les pieds de support sur les côtés de l'appareil - 2 vis pour chaque pied. Ne pas serrer les vis. A. Boîte du moteur de ventilateur B. Pied de support 7. Faire intervenir 2 personnes ou plus, insérer le système d’extraction par le bas dans l'ouverture découpée dans A.
  • Page 30 5. Incliner la patte supérieure de la boîte du ventilateur pour la 3. Débrancher le connecteur du câblage du moteur du ventilateur. placer en affleurement avec le panneau de la boîte du système d’extraction et la positionner sous la bride de montage supérieure.
  • Page 31 7. Brancher le connecteur du câblage sur le moteur du 10. Placer la patte inférieure de la boîte du ventilateur dans le ventilateur. profilé de montage inférieur. A. Boîte du système d’extraction B. Profilé de montage inférieur A. Moteur du ventilateur B.
  • Page 32 Montage du ventilateur à l'arrière REMARQUE : Position de montage du ventilateur facultative 2. Dégager la boîte du ventilateur du profilé de montage (côté opposé). On peut également déplacer la boîte du moteur du inférieur en la soulevant. ventilateur du côté opposé (arrière) du circuit d’évacuation. A.
  • Page 33 5. Dégager le panneau du profilé de montage inférieur en le 8. Faire basculer l’onglet supérieur de la boîte du ventilateur de soulevant. façon à ce qu’il soit en affleurement avec le panneau de la boîte du système d'extraction et le placer sous la bride de montage supérieure.
  • Page 34 Achever l'installation Raccordements électriques 1. Connecter le clapet anti-reflux au raccord d’extension de 6". AVERTISSEMENT Le fixer avec la bride de fixation. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche.
  • Page 35 4. Connecter ensemble les deux connecteurs blancs avec un Pour des renseignements sur la commande, voir la section connecteur de fils (homologation UL). “Assistance ou service”. A. Garniture supérieure B. Bouton Marche/Arrêt C. Bouton de commande du ventilateur D. Embout E.
  • Page 36 UTILISATION DU SYSTÈME D'EXTRACTION La fonction du système d’extraction par le bas est d'aspirer et 2. Pour sélectionner la vitesse du ventilateur, utiliser le bouton évacuer hors de la cuisine les vapeurs et fumées de cuisson, de commande (côté droit) du système d’extraction par le bas. sources d'odeurs.
  • Page 37 SCHÉMA DE CÂBLAGE RÉGULATEUR BOUTON POUSSOIR DE VITESSE HAUT/BAS Fusible temporisé, 5x20 800 mA FUSIBLE MOTEUR ROUGE ROUGE NOIR NOIR (ENGRENAGES) COMMUTATEURS (FILTRE) GRIS GRIS CÂBLE PLAT TRANSFORMATEUR TOROÏDAL VDR1 (connecteur) (connecteurs) ORANGE GRIS GRIS BLANC BLANC NOIR BLANC MARRON BLEU L1 (phase) ELDD...
  • Page 38 Téléphonez au marchand qui vous a vendu l'appareil ou Si vous avez besoin de commander des pièces de rechange, téléphonez à Jenn-Air en composant au 1-800-807-6777 pour nous vous recommandons d’employer uniquement des pièces localiser une compagnie de service autorisée. Lors d'un appel, spécifiées par l’usine.
  • Page 39 5. Les défauts apparents, notamment les éraflures, les bosses, fissures ou tout autre dommage au fini du gros appareil ménager, à moins que ces dommages soient dus à des vices de matériaux ou de fabrication et soient signalés à Jenn-Air dans les 30 jours suivant la date d’achat.