Troubleshooting
If your BUFFALO appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
The appliance is not working
Appliance does not reach set
temperature
Appliance heats up but indicator light
does not come on
Power indicator light comes on but
appliance does not heat up
Power indicator light comes on
but appliance does not heat up
Appliance slow to heat up
Technical Specifications
Model
Voltage
P106
230V 50Hz
L513
230V 50Hz
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Probable Cause
The appliance is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Faulty thermostat
Faulty element
Bulb has expired
Faulty element
Faulty thermostat
Thermostat set incorrectly
Cooking surface not clean
Faulty element
Power
Current
2000W
8.7A
2200W
9.6A
Check the appliance is plugged in correctly
and switched on
Call BUFFALO agent or qualified technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Check thermostat
Clean cooking surface
Call BUFFALO agent or qualified
technician
Griddle Plate
Dimensions w x d (mm)
-
515 x 330
Action
Dimensions
Weight
h x w x d (mm)
(kg)
282 x 517 x 415
9.6
305 x 480 x 525
28.5