8.

Technical data

8.1

Measuring functions

8.1.1

Engine test

Measuring functions
Speed
Oil temperature
U‑battery
U terminal 15
U terminal 1
Ignition voltage,
Spark voltage
Spark duration
Relative compression via starter current
U alternator ripple
I starter
I Alternator
I Spark plugs
I Primary
Closing angle
Closing time
Ignition point,
Ignition advance with stroboscope
Start of delivery, Start of injection,
Injection timing
with stroboscope
Pressure (air)
Pulse‑duty factor t‑/T
Injection time
Glow time
8.1.2
Multimeter
Measuring functions
Speed
U battery
U term. 15
U‑DC/AC
min./max.
I‑1000 A
I‑30 A
Resistance
(R Multi 1)
Pressure P‑air
Oil temperature
Air temperature
Fluid pressure
The measuring range is greater than the permissible measurement voltage
1)
Robert Bosch GmbH
Measuring ranges
450 min
– 6000 min
‑1
‑1
100 min
– 12000 min
‑1
‑1
250 min
– 7200 min
‑1
‑1
100 min
– 500 min
‑1
‑1
‑20 °C – 150 °C
0 – 60 V
0 – 60 V
0 – 20 V
±500 V
±50 kV
0 – 6 ms
0 – 200 Ass
0 – 200 %
0 – 1000 A
0 – 30 A
0 – 100 %
0 — 360 °
0 – 50 ms
0 – 60 °KW
0 – 60 °KW
‑800 hPa – 1500 hPa
0 – 100 %
0 – 25 ms
0 – 20 ms
Measuring ranges
Resolution
as for engine test
0 – 60 V
0,01 V
0 – 60 V DC
0,1 V
1)
±200 mV – ±20 V
0,001 V
0,01 V
±20 V – ±200 V
1)
±1000 A
0,1 A
±30 A
0,01 A
0 – 1000 Ω
0,001 Ω
1 kΩ – 10 kΩ
0,1 Ω
10 kΩ – 999 kΩ
100 Ω
0,2 hPa – 2500 hPa
0,1 hPa
‑20 °C – 150 °C
0,1 °C
‑20 °C – 100 °C
0,1 °C
0 – 10000 hPa
10 hPa
Technical data | FSA 740 | 27
Resolution
Sensors
10 min
Connecting cable B+/B–
‑1
10 min
Trigger clamp,
‑1
Secondary sensor,
Primary connecting cable (UNI 4)
10 min
Current clamp 30A
‑1
Diesel clip‑on sensor,
10 min
Current clamp 1000 A (starter current)
‑1
0,1 °C
Oil temperature sensor
0,1 V
Connecting cable B+/B–
0,1 V
Primary connecting cable (UNI 4)
50 mV
Primary connecting cable (UNI 4)
1 V
Primary connecting cable (UNI 4),
100 V
Secondary sensor
0,01 ms
Primary connecting cable (UNI 4),
Secondary sensor
0,1 A
Primary connecting cable (UNI 4),
Secondary sensor
0,1 %
Multi measuring cable CH1
0,1 A
Current clamp 1000 A
0,1 A
Current clamp 30 A
0,1 %
Primary connecting cable (UNI 4)
0.1 °
0,01 ms
Secondary sensor
0,1 ms
Current clamp 30 A
0,1 °KW
Trigger clamp
0,1 °KW
Clip‑on sensor
1 mbar
Air pressure sensor
0,1 %
Multi measuring cable CH1 / CH2
0,01 ms
Multi measuring cable CH1 / CH2
0,01 ms
Multi measuring cable CH1 / CH2
Sensors
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Multi measuring cable CH1 / CH2
Current clamp 1000 A
Current clamp 30 A
Multi measuring cable CH1
Air pressure sensor
Oil temperature sensor
Air temperature sensor
Fluid pressure sensor,
Oil pressure sensor
1 689 979 895
en
|
2014-10-28