AND IF THE DEHUMIDIFIER DOES NOT START OR DEHUMIDIFY ?
First make sure that the red light 'POWER' is 'ON': this means that the current is fed to the machine. If the power supply light is not
on, make sure that the connecting wire plug may be properly inserted into a main line socket in the room. After checking all this, if
the power light is still off, then call the dealers service.
Make sure that the green light 'FULL' be off; If this is not the case, check the correct position of the draining pipe (see point 4.)
Make sure that the red light 'RUNNING' be 'on'; this means that the Humidostat activates the functioning of the machine. When
the dehumidifier is set again to functioning, after an idle period due to the reaching of the preset humidity or after emptying the
water tank, if the Humidostat requires functioning of the machine, then beside the two red central lights, also the red light 'Pause'
will light up. During this 5 minutes long phase, only the motor fan is running whereas the compressor is off. This operating cycle
take place every 45 minutes to allow the defrosting of the cooler. When the red light 'Pause' will remain off for a period longer than
6 minutes, the dehumidifier should be brought to Dealer's service centre.
When the machine appears to be working correctly ( the two central red lights are on), but it is not producing condensed wate r or
produces only very little condensed water, it should be checked whether the relative humidity in the room may be lower than
40.45%; if the relative humidity is higher than that, the machine should be controlled by the dealer's service.
6. CONNECTION TO A DRAIN PIPE - LIFTING PUMP (optional)
This
dehumidifier
can
connected directly with a fixed
draining pipe; in this case, the
water tank and the fitting of plastic
(see figure) must be removed to
allow for the connection of the pipe
to the connection fitting.
For the connection, use one pipe
provided with a ¾" female fitting at
one end.
Machines with condensed water lifting pumps
This machine includes a condensed water lifting pump.
Put the rubber pipe of the pump supply in a waste pipe or similar. Pay
attention that the pipe be no choked up because of eventual narrow bends.
The pump will work automatically, controlled by a ball cock placed inside the
pump.
Before moving the machine, push the button placed on the pump to empty
the tank of the pump.
If the pump cannot work correctly, the compressor stops and the green light
turns on. In this case, check the pipe situation. Maximum head working
pressure of the pump is about 3.5-4 meters.
AIR FILTER CLEANING
The only required periodical maintenance is the cleaning of the filter once every month, or more often if the environment is very
dusty or the dehumidifier is working for many hours every day.
The cleaning must be done by placing the filter under a water jet with the drilled panel facing the floor so that the water jet may
push the filter towards the drilled panel.
After a few years running, may be necessary to make a cleaning of the warm heat exchanger (condenser) by using compressed
air. This operation must be done by a specialized technician. This cleaning will improve the performances and the long life of the
machine.
Note: You can require spare filters from your dealer's service.