With reference to the drawing (fig. 1), the air is drawn in through the back side of the dehumidifier, then it passes through the filter
(1), through the aluminium refrigerated coil or evaporator (2), again trough the heat- exchanger or condenser (3). Finally, the
motor fan (4) expels the air back into the room through the front grilled panel: The condensed water is collected in the tank (5). A
micro-switch (6) stops the machine when the water in the tank reaches the correct level by raising the water float lever. The
humidistat (7) starts the functioning of the dehumidifier when the humidity his higher than the preset level. An electronic circuit
(8) controls the defrosting and prevents the compressor (9) repeated starts within too short a time by delaying each new start.
Some models have a different water tank stop device and use a gravity system ( fig. 2) instead of the floating ball.
Fig. 3 refers to the machine provided with lifting pump, which includes a water collection tank (5) and a floating ball stopping device
for full tank (6), in case the pump would not unload properly.
.
Machines provided with Hot Gas Defrosting System
The models with hot gas defrosting system have one by-pass solenoid valve and a special electronic card.
The functioning of Hot Gas Defrosting is an exclusive system for the dehumidifiers: this system consists of a thermostat and one
electronic control, which use the hot gas by-pass system only when it is necessary and for the period of time required; this will
lengthen the life of the machine by reducing the hot gas functioning phases.
.
In the position "CONT", the machine will keep running all the time, independently from the relative
humidity in the room.
Before starting the dehumidifier, make sure that the machine has been standing in vertical position for at-least 8 hours. If one fails
to observe this procedure, irreparable damage may be caused to the compressor. Then one can proceed and connect the
dehumidifier plug to a 230 V - one phase power socket.
The red light 'POWER' will switch on confirming correct supply of power to the machine. If the light 'WORKING' is still off, turn
clockwise the knob on the control panel till the light 'WORKING' is ON. The light 'DEFROST (PAUSE) will also switch on and , after
about 5 minutes the dehumidifier will start dehumidifying.
When the red light is "ON" (ALARM), the machine will not start: one must check that the water tank be empty and, then, that be set
in correctly; with the machines provided with pump, check that the pump function be working and that the delivery pump may be
clear.
4. CONTROL AND DISPLAY PANEL
The Control Panel is always placed on the upper side of the machine and consists of 4 lights
indications:
POWER (Supply): red light which turns on when the electric power arrives at the machine;
FULL (ALARM): green light which turns on when the water tank is full, or when the lifting pump is not
working properly and then it fills up the water tank. When this light is on, the machines will stop
running.
DEFROST: red light which turns on when the compressor is in 'pause or idle' position for the
programmed delayed start off at first start up of the machine, or during the defrosting phases.
WORKING (RUNNING): red light on when the dehumidostat starts up automatically the functioning of
the machine.
May be placed on the front or rear side of the machine.
It consists of a number scale ranging from 1 to 5 or from 1 to 7. The minimum value correspond to
80%, the highest value to 20%; the intermediate value (3-4) indicates that the humidity is at approx.
55%, a suggested good general value.
In position "OFF", the machine is not running and will never start running (one-pole switch)
5. FIRST STARTING OF MACHINE
CONTROL PANEL
DEHUMIDOSTAT
HOUR COUNTER
Some models are equipped with an Hour Counter which is normally
located in the rear side of the machine: this will show the hours that the
machine has been
working.
.