PROBLEM
The mower
unexpectedly
stops while
mowing.
56-VOLT LITHIUM-ION COMMERCIAL 22" LAWN MOWER — LMX5300SP/LMX5300SP-FC
CAUSE
The battery pack(s) charge is
depleted.
Mower is overloaded and the
mower status indicator flashes
orange.
Mower deck is clogged with
grass and debris.
The battery pack(s) or mower
circuitry is too hot. If the battery
pack is overheated the mower
status indicator goes off. If the
mower is overheated the mower
status indicator glow solid
orange.
The blade speed mode is not set
properly.
The mower electronics error
and the mower status indicator
flashes red/green alternately.
SOLUTION
Charge the battery pack(s).
Check if grass has accumulated
beneath the deck and clean if
needed. Raise the cutting height
or slow down the mowing.
Unclog the mower deck. Raise
the cutting height and/or cut a
narrower swath.
Allow the battery pack(s) or
mower to cool down.
Clean the air intake, following
the section "
Cleaning the Air
".
Intake
Select the blade speed to a
lower setting.
Contact EGO Customer Service.