Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation mode setting
MODE>***
Use this to set the operation mode of the CLOCK OUT connectors.
A.GND (Adaptive Zero Ground)
The amp is used to drive the negative connector so that it
becomes 0 V.
NORM
This outputs a clock signal with normal output.
Frequency mode setting
FREQ>***
Set the clock reference frequency to 44.1 kHz or 48 kHz. Use an EXP
mode to increase the range of output frequency options that can be
used.
o Set the reference frequency according to the playback source.
44.1 kHz
Use for playback of CDs, Super Audio CDs and other 44.1kHz
sources.
48 kHz
Use for playback of DVDs, DATs and other 48kHz sources.
(Some DVDs and DATs are recorded at 44.1  kHz. In this case,
use the 44.1kHz setting.)
o 100  kHz and 10  MHz can be output regardless of the selected
setting.
44
Sets the reference frequency to 44.1 kHz.
The frequency can be set to 44.1, 88.2, 100 or 176.4 kHz or 10 or
22.5792 MHz.
48
Sets the reference frequency to 48 kHz.
The frequency can be set to 48, 96, 100 or 192  kHz or 10 or
24.576 MHz.
44EXP
Sets the reference frequency to 44.1 kHz.
The frequency can be set to 44.1, 88.2, 100, 176.4, 352.8 or
705.6 kHz or 1.4112, 2.8224, 5.6448, 10, 11.2896 or 22.5792 MHz.
48EXP
Sets the reference frequency to 48 kHz.
The frequency can be set to 48, 96, 100, 192, 384 or 768 kHz or 1.536,
3.072, 6.144, 10, 12.288 or 24.576 MHz.
Display illumination time setting
DISP>***
You can set the amount of time that the clock frequency is shown on
the display to ON, LONG or SHORT.
o We recommend setting this to LONG or SHORT because display
brightness irregularities might occur if the same information is
shown without change for a long time.
ON
In this mode, the display always stays lit.
Set the brightness of the display with the dimmer setting.
LONG
When ordinary display continues without any operation being
conducted for about 20  seconds, the display will automatically
turn off.
SHORT
When ordinary display continues without any operation being
conducted for about three seconds, the display will automatically
turn off.

Dimmer setting

DIMMER>***
When the display illumination time setting (DISP) is ON, you can
adjust the brightness of the unit's display and indicators.
o You can also change this setting using the DIMMER button on
a remote control that is included with another Esoteric product
such as the P-02X, K-01X or K-03X.
3
c
2
(normal brightness)
c
1
c
0
(off )
o When set to "DIMMER>0", the display will not be lit.
o When unlit, pressing a button will cause the display to light for a
few seconds.
o When set to a value other than "DIMMER>3", error messages
and settings menu items will be shown at normal brightness
("DIMMER>2").
15