Do not provide children access to the multimeter. Parents are fully responsible for
any safety hazards caused by non-compliance.
Please be careful if the measurement exceeds 30V AC True RMS, a 42V AC peak,
or 60V DC. There might be the danger of getting an electric shock with this kind of
voltage. Follow all relevant safety requirements.
When measuring known voltage, in order to check if the multimeter works normally,
results in the multimeter not working normally or being damaged, stop any
measuring operation and do not continue using the multimeter.
Before using the device, please check whether it has any crack or plastic damage.
If so, do not use the device.
Before using the instrument, please check whether the probes are cracked or
damaged. If so, please replace them with the same type, having the same electrical
specifications.
The instrument shall be used in accordance with the specified measurement
category, voltage, or current rating.
Do not exceed the max. input values as specified in this manual.
Never change the measurement function during a measuring operation on an object
or circuit. Always disconnect the measuring object/circuit first.
Opening, repairing, or maintenance should only be executed by trained/qualified
professionals.