Before You Begin
The LMCUS11100 lights must be used with a LMCUSPS005 junction box driver. Do not attempt to
power the lights directly to a power supply. The LMCUSPS005 junction box driver requires low volt-
age (12 volt) power only. Do not connect high voltage to the junction box driver.
Cord Length and Minimum Required Voltage
When installing ColorLogic ½" LED low voltage system, the length of the power input cord has an
effect on performance. To prevent performance problems, verify the transformer is providing the
minimum required voltage according to the table below. To check this voltage, measure the voltage
at the transformer while the light is "on" and operating in "white" mode. In some cases, a voltage
greater than 12 volts is required due to a long cord run. Some transformers provide higher voltage
taps for this purpose; check your transformer manufacturer's installation instructions for details.
When using Hayward or other transformers that offer a 14v option, we suggest that you always use
the 14 volt tap.
NOTE: Environmental conditions and long cord lengths (over 100') could cause a voltage drop that
may result in decreased brightness.
Total Cord Length
from Transformer
to Junction Box
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Installation
Minimum Required
Driver
30 ft
50 ft
100 ft
Voltage at
Transformer
12 - 14 volts
13 - 14 volts
14 volts