WARNING! This motor must not be installed upside down. The fan should be installed in such
a manner that maintenance and repair operations can be carried out simply and safely. Noise
disturbance can be avoided by installing a silencer (Not included, but available).
ATTENTION! This motor complies with IP55 rating, and outer shell IP25, regarding protection
and waterproofing. It is very important to seal the joint of the motor base and the
used and unused orifices of the motor base attachment bolts. To seal the base, use sealer
or a product designed for the material it is to be joined to. Check that all the elements and
accessories included with the product have been fitted. Once the motor has been installed,
we recommend simulating rainfall on the motor from above to check the sealing
(Do not spray water from the side onto the motor, as this could cause damage and leakage
into the building), make sure there are no leaks inside, through the orifice, the conduit or the
electric cable to the hood. If any leaks are discovered, this will indicate that the sealing is
incorrect.
Inoxpan S.L. will not be held liable for damage caused to the product or the home due to water
leaks caused by incorrect installation, sealing or verification.
DUCTING:
Should be installed with a Ø200mm conduit, a different diameter will affect the
performance of the motor, reducing its suction capacity, increasing noise produced
as well as causing other problems.
The recommended length of the conduit between the hood and the motor is 12m
maximum (V2350N ECO) and 18m maximum (V3300N ECO), a greater distance will
reduce the motor's suction capacity, while a shorter
of the hood, if the latter case in inevitable, we
soundproofing elements.
It is recommended that the conduit from the hood to the motor is without sharp
angles, as they will reduce the suction capacity of the motor. If they are inevitable,
try to ensure they are not too close to the inlet or outlet of the motor (at least 0.5m
away). Do not use elbow joints of less than 90º, or place one after another, the
minimum recommended distance between them is 1m, and try to make them as open as
possible.
The maximum total length of the conduit from the hood to the exterior should be 12
linear metres (V2350N ECO) and 18 linear meters (V3300N ECO), and a minimum of
4 m , not counting elbow joints (one elbow joint is
ES – INSTALACIÓN
WARNING! Please read this user's manual carefully before installing the motor.
Before installing, check that the diameters of the fume outlet correspond to those indicated in the
specifications table.
Do not manipulate the internal connections in the motor box. Do not plug the motor directly into
the mains socket, it should always be connected through the hood, following the connection
instructions.
Your model may differ from the models described here, to see the characteristics of your specific
model please refer to the exterior motor data sheet.