10. (Rectangular Ducting) From inside the liner,
push 3-1/4" x 10" rectangular adaptor through
the back knock-out and secure to interior back
wall of liner with (8) M4 x 6mm screws.
11. Secure (2) horizontal ducting blower brackets
to blower as shown above by using the (4)
3/16" x 3/8" screws previously removed from
Page 12, Step 6; (2) screws for each bracket.
13. Secure blower to captive nuts on interior
back wall of liner with (8) 3/16" x 3/8" screws,
(4) screws for each bracket. Seal any gaps
around the knock-out plate by using certifi ed
aluminum duct tape. Plug in blower molex
plug.
10. (Round Ducting) From inside the liner, push
8" round adaptor through the back knock-out
and secure to interior back wall of liner with (4)
M4 x 6mm screws.
12. Position blower inside liner body as shown by:
1) Rest the bottom horizontal ducting bracket
on the two support clips located on the interior
back wall of the liner. 2) Pivot top horizontal
ducting bracket to meet captive nuts on interior
back wall.
Horizontal ducting preparation is now
Horizontal ducting preparation is now
complete. Refer to Page 10, Step 5 to
complete. Refer to Page 10, Step 5 to
complete installation.
complete installation.
14