Télécharger Imprimer la page

camry CR 7851 Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Efficiency
1. The appliance automatically performs defrosting in regular intervals according to the room temperature.
a) If room temperature is equal or exceed 24°C, the defrosting is stopped.
b) If room temperature is 18°C -24°C, the defrosting is turned on for 5 minutes after every 120 minutes of dehumidification.
c) If room temperature is 12°C -18°C, the defrosting is turned on for 5 minutes after every 25 minutes of dehumidification.
d) If room temperature is 5°C -12°C, the defrosting is turned on for 5 minutes after every 20 minutes of dehumidification.
2. During the defrosting operation, the dehumidification function may be intermitted.
3. Please don't turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation.
4. This dehumidifier can't be applicable to keep extreme low temperature. The function of this dehumidifier is to pump off the unpleasant,
high humidity.
Dehumidifying capacity
1. This dehumidifier doesn't have cooling function. It will produce heat during the operation and increase the room temperature by 1-4°C.
2. The daily dehumidifying capacity of the dehumidifier depends on room temperature and relative humidity. At different temperatures and
relative humidity, it may have different dehumidifying capacity.
3. In the same room temperature, the dehumidifying capacity is higher in higher relative humidity and the dehumidifying capacity is lower in
lower relative humidity. In the same relative humidity, the dehumidifying capacity is higher in higher temperature and the dehumidifying
capacity is lower in lower temperature.
4. If the dehumidifier is placed in the cabinet, its dehumidifying capacity may highly reduce in a short period after operating due to the
humidity in the cabinet has been highly reduced.
5. For 5°C / 10°C / 15°C /20°C /25°C / 30°C of room temperature and 80% of relative humidity the dehumidifying capacity is respectively
around 2 / 4 / 6 / 8 /10 liters of water when the air outlet is fully open.
Humidity indicator light (10)
During operation, the humidity indication light shows current humidity level in room:
-
Blue color means low humidity below 50% relative humidity
-
Green color means medium humidity in range 51% - 69% relative humidity
-
Red color means high humidity over 70% relative humidity
Please note, the relative humidity value has got 3% tolerance when illuminates up the corresponding indication light.
Operation
1.Please place the machine unit upright to avoid misoperation and unusual sound. Keep distances between other objects like shown at
picture 1. Plug in the device.
2.Power switch (A) on the control panel (1) should be pressed to turn on the device. The digital display (L) will show present humidity level
in room.
3.Mode button (B) should be pressed again to choose desired operation mode between:
B1. Ordinary dehumidification mode
When choose this mode, the indicator B1 will light up.
B2. Continuous dehumidification mode
When choose this mode, the indicator B2 will light up.
B3. Strong dehumidification mode
When choose this mode, the indicator B3 will light up.
B4. Clothes drying mode
When choose this mode, the indicator B4 will light up.
4. Humidity setting button (H) should be pressed again to set up desired room humidity between 30-80% with 5% adjustment factor.
Humidity setting is valid under ordinary dehumidification mode (B1) only. After set up required room humidity the digital display (L) will
flashing to remember it and device start to operate. Next at the digital display (L) is shown present room humidity. It is need to set up
required room humidity at lower level than present room humidity, otherwise the device will not start dehumidification. When the relative
humidity in the room equals the level of relative humidity previously set on the display, the device will automatically turn off the compressor,
the dehumidifier will stop, only the fan will work.
5. Timer button (C) operates two functions:
DELAY START function
The timer can be set when the device is in the off status. Press the timer button ©: "Hr" indicator (C1) at the LED display lights up and "00"
will appear on the digital display (L); within 5 seconds, you should press the timer button (C) to select the desired time when the device
must switch on. Once the timer has been set, the time will be displayed for 5 seconds, the " Hr " indicator (C1) will be on. The device will
switch on automatically after set up time passed.
Setting the Timer OFF function - DELAY STOP
The timer off function can be set when the device is in switch on status. Press the Timer button ©: the "Hr" indication (C1) at the LED
display lights up and "00" appears on the digital display (L); within 5 seconds, you should press the timer button (C) to select the desired
time for the device to switch off. After the timer is set, the time will be displayed for 5 sec and the "Hr" indicator (C1) turns on. The device
will switch off automatically after set up time passed.
The timer range is from 1 to 24 hours with a 1-hour interval.
6. Additional fan mode button (D) should be pressed to active or reactive air circulation in addition to fan operation. When this fan mode is
6

Publicité

loading