INSTALLATION
Installing/Replacing the lamp
For the installation, you need one MSD 250/2 GY-9.5 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter regularly and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
39/120
(18) Power supply
(19) Fuseholder
(20) DMX-Out socket
(21) DMX-In socket
51838205_V_1_1.DOC