Refi lling the burner
Never pour fuel into the burning fl ame!
Allow the burner to cool down for at least 15 minutes before refi lling.
Do not refi ll the ethanol fuel while there is fl ame or heat in the burner.
Extinguish fl ame
Let the fuel burn out completely if possible. This prevents alcohol left in
the reservoir and defl agration when reigniting.
If you wish to extinguish the fl ame before the fuel has completely
burned out, use the slides provided to close the burner opening. Wait
approximately 30 minutes until the burner has reached room temperature.
Only then dispose of the remaining fuel.
Use only the extinguishing tool supplied with this device, never use a
wooden or plastic tool and never your bare hands.
The valve must always be fully open during operation so that no pressure
can build up inside the burner.
To extinguish the fi re, quickly pull the slide to the front of the burner. If the
fi re is not extinguished, open the slider again and repeat the extinguishing
process.
CAUTION
Risk of fi re! Never try to extinguish the fl ame with water!
Fuel storage
Fuel shall be stored in a fi re-safe area.
Open
Close