LoRaWAN PULSE - Mode d'emploi / User guide version V1.6.1
1.3. Electronic board
1.4. Technical specifications
1.4.1 General characteristics
Parameters
Power supply voltage
Power supply
Operating temperature
Dimensions
Case
Radio standards
1.4.2 Product input tolerance characteristics
Parameters
Min. pulse width
Max. pulse frequency
Max current (open collector version)
Input resistance (dry contact version)
Max. voltage
1.4.3 Battery life
Conditions of use
Product storage before use:
1 year maximum.
Calculations carried out at
a temperature of 20°C
1.4.4 Operating modes
The LoRaWAN PULSE unit has two operating statuses (modes):
•
STANDBY: This is the mode in which you receive your product or the default mode after having (re)configured your product (no radio
frames transmission).
•
OPERATION: This is the mode in which the LoRaWAN PULSE unit transmits frames periodically.
Value
3.6 V nominal
Integrated Li-SOCl2 battery (radio management and querying of meters)
-25°C / +70°C
105 x 50 x 27mm
IP 67
EN 300-220, EN 301-489
Value
8ms
33Hz
1mA
1kOhm
3.6V
Transmission frequency
140 frames per day
140 frames per day
100 frames per day
100 frames per day
50 frames per day
50 frames per day
20 frames per day
20 frames per day
2 frames per day
2 frames per day
Number of meters
battery life (in SF7)
1
2
1
2
1
2
1
2
1
2
0.5 year
0.5 year
0.7 year
0.7 year
1.3 year
1.3 year
3 years
3 years
+10 years
+10 years
Page
28