■ Provide at least 8 of space between the product and
the wall.
- Being too close to the wall may cause product failure.
■ For cleaning or servicing, unplug the power cord, close the feed
water valve, and wait until the product comes to a complete stop.
- Otherwise, electric shock or physical injury may result.
■ Remove the dust on the Condenser, which is on the front or side
of the product, at least once a month.
- Heavy dust on the Condenser prevents heat dissipation and deteriorates
the product performance, leading to excessive power consumption and/or product
failure.
■ The ambient temperature range must be between 50 to 104
- If installing in a cold place 0℃(32℉) or below, freeze break may occur.
- If installing in a hot place 40℃(104℉) or over, product failure may occur.
■ The pressure and temperature of the supply water must be
1kgf/㎠~5kgf/㎠(14.22 psig - 71.12 psig), and
50℉~ 89.6℉, respectively.
- If the pressure or temperature of the supply water exceeds the above specified
ranges, the ice quality may deteriorate and/or product failure may occur.
■ Make sure to connect the product with a cold water line.
- Connection to a hot water line may cause product failure.
■ The supply water must be from the top water.
8