voLtagE BaLancing anD Monitoring DUring tHE DiScHargE
The processor monitors the voltage of individual cells during "storage-mode" and "discharge" of Lithium
battery pack. It tries to normalize the voltages to be equal. For this feature, the individual plug of the
battery pack should be connected to the individual port of the charger.
If the voltage of any one or more cells varies abnormally during the procedure, it terminates the process
forcibly with the error message. If this happens, the battery pack contains the bad cell, or the bad
connection of the cable or plug. You can easily know which one cell is bad by pressing INC button at time
of showing the error message.
BATTERY VOL ERR
CELL LOW VOL
4.14
4.16
4.09
2.18
0.00
0.00
niMH/nicD BattEry prograM
These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium)
battery commonly used for R/C models applications. To alter the value at the display, press Start/Enter
key to make it blink then change the value using INC or DEC key. The value will be stored by pressing Start/
Enter key once.
NiMH 2.0A 7.42V
CHG 022:45 00890
cHarging nicD/niMH BattEry
NiMH CHARGE Aut
CUR
LIMIT
5.0A
mode. But in "Man" mode, it will charge the battery with the charge current you set at the display. Each mode can
be switched by pressing INC and DEC button simultaneously when the current field is blinking.
The screen displays the current state of charging. To stop the process, press Batt type/Stop key once.
The audible sound indicates charge you the end of process
DiScHarging nicD/niMH BattEry
NiMH
DISCHARGE
1.0A
11.5V
NiMH
1.0A
7.42V
DSC 022:45 00890
The processor found that the voltage of one of the cell in the Lithium battery
pack is too low.
In this case, the 4th cell is bad. If there happens the connection-break of the
cable or plug, the voltage value may show zero.
To start the process, press Start/Enter button for more than 3 seconds.
This program simply charges the battery using the current you set. In "Aut" mode,
you need to set the upper limit of charge current to avoid from higher feeding current
that may damage the battery. Because some batteries of low impedance and small
capacity can lead to the higher charge current by the processor at automatic charge
Set discharge current on the left and final voltage on the right. The discharge
current ranges from 0.1 to 2.0A and the final voltage ranges from 0.1 to
25.0V. To start the process, press Start/Enter key for more than 3 seconds.
The screen displays the current state of discharge. You can alter the discharge
current by pressing Start/Enter key during the process. Once you change the
current value, store it by pressing Start/Enter button again.
To stop discharging press Batt type Stop key once. The audible sound indicates
you at the end of process.