8. Soldering of cables at IP67 Flex Strips
If you have to solder a connection to a Flex Strip IP67, please work according to following steps. Please be advised,
that correctly sealed end caps have only a IP65 classification.
Cut the Flex Strip on marked cutting line.
Cut a hole for power cable into the end cap.
Pierce the tube outlet with the cap of the sealing
glue, for example PROLED L6396.
MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg - Germany
Montageanleitung / Installation manual
Remove the silicone from the soldering pads.
Solder the cable correctly . Please take care about
correct polarity.
4
Move the end cap over the cable.
Screw the outlet funnel on the tube.
www.proled.com