9.2 Cleaning the spray arms
Do not remove the spray arms.
If the holes in the spray arms are clog-
ged, remove remaining parts of soil with
a thin pointed object.
9.3 External cleaning
Clean the appliance with a moist soft
cloth.
Only use neutral detergents. Do not use
abrasive products, abrasive cleaning
pads or solvents.
10. TROUBLESHOOTING
The appliance does not start or it stops
during operation.
Before you contact the Service, refer to
the information that follows for a solu-
tion to the problem.
With some problems, the display
shows an alarm code:
- The appliance does not fill with
water.
Problem
You cannot activate the appli-
ance.
2.
To disassemble the filter (A), pull
apart (A1) and (A2).
3.
Remove the filter (B).
A1
4.
Wash the filters with water.
5.
Before you put the filter (B) back,
make sure that there are no residues
of food or soil in or around the edge
A2
of the sump.
6.
Make sure that the filter (B) is cor-
rectly positioned under the 2 guides
(C).
7.
Assemble the filter (A) and put it
back in filter (B). Turn it clockwise
until it locks.
9.4 Internal cleaning
If you regularly use short duration pro-
grammes, these can leave deposits of
grease and limescale inside the appli-
ance.
To prevent this, we recommend to run
long duration programmes at least 2
times per month.
the water.
Possible solution
Make sure that the mains plug is connected
to the mains socket.
An incorrect position of the filters
can cause bad washing results
and damage to the appliance.
- The appliance does not drain
- The anti-flood device is on.
WARNING!
Deactivate the appliance before
you do the checks.

Publicité