Télécharger Imprimer la page

United States Stove KING KP5513 Manuel D'instructions Et D'utilisation Du Propriétaire page 15

Publicité

OPERATION INSTRUCTIONS
shut down the auger, preventing the stove from
overheating.
NOTE: On some units, once tripped, like a circuit breaker,
the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset
button and will reset itself once the stove has cooled.
The manufacturer recommends that you call customer
service if this occurs as this may indicate a more serious
problem. A service call may be required.
2. If the combustion blower fails, an air pressure switch
will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds
during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove
will shut down and show "E2" on the two digit display.
The stove has to fully shut down before restarting.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA to
meet strict 2020 guidelines. To Insure this unit produces
the optimal minimal emissions, it is critical to follow
the following guidelines.To achieve a "high burn" your
stove should be set on setting 5 with the damper fully
open.To achieve a "medium burn" your stove should be
set on setting 1 with the damper fully closed.To achieve
a "low burn" your stove should be set on setting 1 with
the damper closed.Settings 2,3 & 4 will give you a higher
heat output above medium and the damper should be
open for these settings. If the door is opened while the
stove is in operation it must be closed within 30 seconds
or the stove will shut down. If the stove shuts down push
the "On/Off" button to re-start your stove. The stove will
have to fully shut down and turn off before you will be
able to restart the stove
INTERIOR CHAMBERS
• Burn Pot - Periodically remove and clean the burn pot
and the area inside the burn pot housing. In particular,
it is advisable to clean out the holes in the burn pot to
remove any build up that may prevent air from moving
through the burn pot freely.
• Heat Exchanger - There is a clean out plate on both
sides of the heat exchanger that need to be removed to
clean fly ash out of the heat exchanger. The cleanouts
are located inside the cabinet doors, on the lower
front corners of the heat exchanger. To access these
clean outs, you must remove both side panels. The
clean outs are secured to the firebox with (2) 5/16"
screws. Remove the clean outs and vacuum out any
accumulated ash. This should be done at least once per
month or more frequently if large amounts of ash are
noticed while cleaning or if the stove does not seem to
be burning properly.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner
(i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
FAILURE TO PROPERLY MAINTENANCE THE CLEAN
OUTS WILL RESULT IN POOR PERFORMANCE OF
Clean-Out
Plate
15
© 2022 United States Stove Company
WARNING:
THIS STOVE.
Clean-Out
Plate

Publicité