Service tasks
9.11
Changing the drained oil receptacle
I
NOTE
Replace the drained oil receptacle and the O-ring in the lid every
6 months.
If the drained oil receptacle has been damaged, replace it
immediately.
The drained oil receptacle (21) is also leak-proof when there is a vacuum
or overpressure. A safety valve guarantees safe operation.
The drained oil receptacle must be changed every 6 months.
1. Open the cover flap (22) on the left side and remove the drained oil
receptacle (21) from the snap lock:
2. Release the bracket (M) and remove the cover (N).
134
N
VAS 581 001A
21
22
M
EN