Alcove Unit - supported by pedestal/legs and placed
on a non-combustible floor surface in compliance with
clearance requirements for an alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This unit must be installed on a non-combustible floor
surface. If a floor pad is used, it should be certified or
equal. The floor pad or non-combustible surface should
be large enough to extend a minimum of 6" (153 mm) in
front, 6" (153 mm) on each side, and 1" (26 mm) behind
the stove. Floor protection must extend under and 2"
(51 mm) to each side of the chimney tee for an interior
vertical installation. A Floor Protector of 1" (26 mm) thick
is recommended for this installation.
A
B
B
C
A
Rear (through wall)
B
Side
C
Front
D
Rear (interior vertical)
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home/transportable building, and
alcove applications in accordance with the clearances
given in this manual. NOTE: The distance on the side
of your pellet stove may need to be greater than the
minimum required clearance for suitable access to the
control panel. For safety reasons, please adhere to the
installation clearances and restrictions. Any reduction in
clearance to combustibles may only be done by means
approved by a regulatory authority.
© 2023 United States Stove Company
D
1"
25 mm
6"
152 mm
6"
152 mm
2"
50 mm
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME/TRANSPORTABLE BUILDING)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home/
transportable building. You can purchase the 69FAK
through your heater dealer. Installation instructions are
supplied with the air intake kit.
6
INSTALLATION
F
E
G
J
J
E Backwall to unit
F Sidewall to flue
PARALLEL
Sidewall to top edge
G
of unit
H Backwall to flue
CORNER
J Adjacent wall to unit
ALCOVE
K Alcove depth
H
F
G
J
K
9.5"
241 mm
14"
330 mm
8"
203 mm
3"
76.2mm
8"
203 mm
36"
914 mm
(OPTIONAL, UNLESS
J