INSTALLATION OF THE COOKER HOOD
1
Remove the grease filter.
Place the cooker hood at the required position at a minimum height of 65 cm above the cooking section and mark the
bottom side of the cooker hood on the wall/side wall. Determine the centre of the cooker hood.
Determine the centre of the cooking section and mark this point at the height of the cooker hood. This is to be able to
position the cooker hood centred above the cooking section.
2
Determine the position of the air discharge tube. Limit the number of bends and unnecessary lengths in the discharge
tube. As a result, the cooker hood will function better.
Saw out the holes for the discharge tube. The discharge opening has a diameter of 150 mm. The hole for the discharge
tube must be 10 mm larger than the discharge tube (160 mm).
3
Attach the discharge tube on the upper side of the discharge channel and allow it to hang down.
4 See how you want to mount the cooker hood - 4a or 4b.
4a The cooker hood can be attached via holes in the side of the base unit, by means of screws in the kitchen cabinet.
4b The cooker hood can be attached via holes in the top side of the base unit, by means of screws in the kitchen
cabinet. Remove the cooker hood and pre-drill the holes. Use an 8 mm drill. Drill the hole approximately 45 mm
deep.
5
Place the cooker hood back in the kitchen cabinet. When the discharge channel is no longer within reach, you must
connect the discharge tube to the cooker hood before you fully place the cooker hood in the kitchen cabinet.
Now fasten the cooker hood to the kitchen cabinet using the supplied screws.
Place the grease filters back.
Remove all protective film prior to using the cooker hood.
ELECTRIC CONNECTION
Make sure the supply voltage ratings correspond with those stated on the rating plate. Plug the appliance in. The cooker
hood is provided with a plug. Make sure the plug remains accessible. Place the socket, if necessary, out of sight behind the
exhaust-air pipe.
Attention: if you want to make a fixed connection, ensure that a multipole switch with a distance between contacts of 3 mm
is installed in the supply cable.
22
•
English