Fuel supply
8
Fuel supply
The fuel is taken from the vehicle fuel tank or from a separate fuel tank.
The values for the maximum pressure at the fuel extraction point are
shown in Figure 9.
Permissible fuel inflow height
H (m)
0.00
1.00
2.00
Maximum fuel intake height
S (m)
0.00
0.50
1.00
Only for ADR: The statutory regulation of ADR (Accord européen relatif
au transport international des marchandises dangereuses par route)
governing fuel tanks, part 9 para. 9.2.4.7, must be adhered to.
A sign must be affixed to the fuel filler neck warning that the heater must
be switched off before refuelling.
50
All manuals and user guides at all-guides.com
At max. pressure (bar) in fuel
line
0.2
0.11
0.03
At max. negative pressure
(bar) in the fuel tank
-0.10
-0.06
-0.02
≤ 10 m
l
+ l
1
2
≤ 1.2 m
l
2
≤ 8.8 m
l
2
Petrol heaters without dampers
Fig 9:
Fuel supply