3) Installation of the unit
A. Move the unit with the exhaust hose assembly installed in front of window and keep the unit at
least 50cm away from the walls or other objects.
B. Install the rectangle end of exhaust hose assembly into the corresponding rectangle hole in
window seal-plate assembly, fix it with screw and close the window.
Note:
l Slide the adapter downwards and assure adapter installed in good position.
l Assure the slant panel direction to match seal-plate direction.
l Exhaust hose cannot be bent or with flexure higher than 45°, in order to keep good ventilation
of exhaust hose.
Important notes:
The exhaust hose is 280mm-1500mm long and this length is determined based on the
specification of the air-conditioner (s). Do not use prolonged the hose or replace it with other
different hoses as this may affect the functions of the air-conditioner. The exhaust hose must
be smooth or it may lead air-conditioner overheat and damage.