For your Safety
• DO NOT store or use gasoline, or other
flammable liquids in the vicinity of this or
any other appliance. Read product labels
for warnings regarding flammability and
other hazards.
• DO NOT operate the appliance in the
presence of explosive fumes.
• Remove all staples from the carton.
Staples can cause severe cuts, and also
destroy finishes if they come in contact
with other appliances or furniture.
CAUTION
EXCESSIVE WEIGHT HAZARD
To avoid back or other injury, have more
than one person move or lift the appliance.
Shipping Hardware
‰ Foam shipping restraint (inside wash
tub) removed and stored
‰ Foam shipping support (underneath
appliance) removed and stored
Leveling
‰ Laundry center is level, side-to-side and
front-to-back
‰ Cabinet is setting solid on all corners
Water Supply
‰ Use only new hoses and verify rubber
sealing washers are installed
‰ HOT supply is connected to HOT inlet and
COLD supply is connected to COLD inlet
‰ HOT and COLD water supply turned on
‰ No leaks present at water supply con-
nections or appliance inlet connections
-recheck in 24 hours
Drain
‰ Stand pipe or wall drain height min. 33"
‰ Drain hose secured in place with cable
tie (shipped in drum)
Exhaust Venting
‰ Free-flowing, clear of lint buildup
‰ 4 inch (102 mm) rigid or semi-rigid
ducting of minimal length and turns
‰ NO foil or plastic venting material
‰ Approved vent hood exhausted to
outdoors
IMPORTANT SAFETY INSTRUCTIONS
Installation Checklist
Child Safety
Destroy or recycle the carton, plastic bags, and
any exterior wrapping material immediately
after the appliance is unpacked. Children
should never use these items for play. Cartons
covered with rugs, bedspreads, plastic sheets
or stretch wrap may become airtight chambers,
and can quickly cause suffocation.
WARNING
ELECTRIC SHOCK HAZARD
Certain internal parts are intentionally not
grounded and may present a risk of electrical
shock if contacted during installation. Do
not contact the following parts while the
appliance is energized:
• Pump
• Drive Motor
• Electronic control boards
• Water valve
Gas Supply (Gas Dryer)
‰ Manual shutoff valve present in supply
‰ All connections sealed with approved
sealer and wrench tight
‰ Conversion kit for LP system
‰ Gas supply turned on
‰ No leaks present at all connections -
check with soapy water, NEVER check
with flame
240v Electric Supply
(Electric Dryer)
‰ Approved NEMA 10-30R or 14-30R
service cord with all screws tight on
terminal block
‰ Approved strain relief installed
‰ Terminal access cover installed before
initial operation
Electrical Power
‰ House power turned on
‰ Laundry Center plugged in
Final Checks
‰ Installation Instructions and Use and
Care Guide read thoroughly
‰ Water enters drum when cycle starts
with lid lowered. Dryer door latches and
drum tumbles when cycle starts.
‰ Registration card sent in
3