INSTALLATION INSTRUCTIONS
Connecting vent
1. Remove the two screws securing the dryer
front access panel to the dryer cabinet. Lift
the panel until the tabs can be disengaged
from the cabinet, remove the panel and set
aside.
2. Connect the exhaust duct to the outside ex-
haust system. Use of a 4" (10.2 cm) clamp
is recommended to connect the dryer to the
exhaust vent system. Use metal foil tape to
seal all other joints.
3. Reinstall the dryer front access panel.
WARNING
ELECTRIC SHOCK HAZARD
Certain internal parts are intentionally not
grounded and may present a risk of electrical
shock if contacted during installation. Do
not contact the following parts while the
appliance is energized:
• Pump
• Drive Motor
• Electronic control boards
• Water valve
18
Screws
Clamp
4. Carefully slide the laundry center to its final
position. Recheck for level and rock corners
for stability.
Connecting drain and electrical
1. Form a "U" shape on the end of the drain
hose with the hose pointed toward the
drain. Place the formed end in a laundry
tub or a standpipe and secure the drain
hose with the cable tie (provided in the
enclosure package) to the standpipe, inlet
hose, laundry tub, etc. so the hose does
not pull out from the force of the water.
Cable Tie
NOTE
The standpipe inside diameter must be
1-1/4" (3.2 cm) minimum. There must be
an air gap around the drain hose in the
standpipe. A snug hose fit can cause a
siphoning action.