Description of internal valves in Hybrid Foamatic SA/MA
Description of sequence for wash steps
Rinsing
Sequence
Activity/function
1
Activate area valve*
2
Activate rinse valve (Q110)
3
Step time – rinsing
4
Deactivate rinse valve (Q110)
5
Action pause (closing of valve)
6
Deactivate area valve
7
Action pause (close of vave)
Foaming
Sequence
Activity/function
1
Activate area valve*
2
Activate product water valve
3
Activate chemical product valve**
4
Action pause
5
Activate air valve
6
Step time – foaming
7
Deactivate air valve
8
Deactivate chemical product valve**
9
Deactivate product water valve
10
Action pause (closing of valve)
11
Deactivate area valve
12
Action pause (closing of valve)
Sanitize
Sequence
Activity/function
1
Activate area valve*
2
Activate product water valve
3
Activate chemical product valve**
4
Step time – sanitizing
5
Deactivate chemical product valve**
6
Deactivate product water valve
7
Action pause (closing of valve)
8
Deactivate area valve
9
Action pause (closing of valve)
Pause
Sequence
Activity/function
1
Step time – pause
Injector pulse flush function
Sequence
Activity/function
1
Activate area valve*
2
Activate product water valve
3
Action pause
4
Deactivate product water valve
5
Action pause
6
Activate product water valve
7
Action pause
8
Deactivate product water valve
9
Action pause
10
Activate product water valve
11
Action pause
12
Deactivate product water valve
13
Action pause
14
Activate product water valve
15
Action pause (opening of valve)
16
Deactivate product water valve
(opening of valve)
(opening of valve)
(closing of valve)
(opening of valve)
(closing of valve)
(opening of valve)
(closing of valve)
Time/valve no. to activate
XX sec.
3 sec.
3 sec.
Time/valve no. to activate
(Q111)
(Q120/Q121/Q122)
3 sec.
(Q112)
XX sex.
(Q112)
(Q120/Q121/Q122)
(Q111)
3 sec.
3 sec.
Time/valve no. to activate
(Q111)
(Q120/Q121/Q122)
XX sec.
(Q120/Q121/Q122)
(Q111)
3 sec.
3 sec.
Time/valve no. to activate
XX sec.
Time/valve no. to activate
(Q111)
10 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
137