ROUGH-IN OPENING DIMENSIONS
MODEL
"A"
24"
MO24BNS
(61 cm)
PRODUCT DATA
ELECTRICAL
MODEL
REQUIREMENTS#
MO24BNS
115V/60Hz/15A
"C"
Figure 9a
If necessary to gain clearance inside the rough-in
opening a hole can be cut through the adjacent cabi-
net and the power cord routed through this hole to a
power outlet. Another way to increase the available
opening depth is to recess the power outlet into the
rear wall to gain the thickness of the power cord plug.
Not all recessed outlet boxes will work for this applica-
tion as they are too narrow, but a recessed outlet box
equivalent to Arlington #DVFR1W is recommended for
this application, (see Figure 11).
PRODUCT DIMENSIONS MO24BN
"B"
"C"
**34" to 35"
*
(86.4 to 88.9 cm)
(60.7 cm)
PRODUCT
WEIGHT
140 lbs
(63.6 kg)
"A"
"B"
"E"
"D"
Figure 9
CABINET DIMENSIONS
"D"
"E"
23
⁄
"
33
⁄
" to 34
⁄
"
7
3
3
8
4
4
(85.7 to 88.3 cm)
"D"
Figure 11
* Depth dimension of rough-in opening may vary depend-
ing on each individual installation. To recess entire door "F"
dimension plus 1" (2.5 cm) for thickness of power cord plug
is required.
** Minimum rough-in opening required is to be larger than
the adjusted height of the cabinet.
# A grounded 15 amp dedicated circuit is required. Follow
all local building codes when installing electrical and appli-
ance.
8
"F"
"G"
"H"
23
⁄
"
26
⁄
"
46
23
1
13
32
4
(60.2 cm)
(66.7 cm)
(117.9 cm)
"J"
"H"
"E"
Figure 10
(54.6cm)
"F"
"J"
⁄
"
26
⁄
"
1
32
4
(66.7 cm)
21
⁄
"
1
2
"G"