Facom B124.1A Notice Originale page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
- The operators are trained and know how to use the booster.
- The vehicle manufacturer's procedures are followed.
- Check that the booster's charge level is sufficient.
- Check that the voltage selection plug is disconnected.
- Check that the booster is placed on a stable surface, either on the ground or on the vehicle.
- First connect the red positive clip + to the vehicle's positive terminal + then connect the black negative clip - .
- Check that the sound alarm and the polarity reversal alarm light are off.
If the alarm is active, disconnect the booster immediately.
- Connect the voltage selector to 12V for a 12V vehicle and to 24V for 24V vehicles.
- Check that the booster and its cables, or any other object or person, are not in contact or near a mobile mechanism inside
the engine. (Belt for example).
- Start the vehicle.
Caution, make sure you do not activate the starter for longer than 8 seconds.
- If several tests are necessary to start the vehicle, wait 3 minutes between two tests.
- Check that the charge level is sufficient between two tests.
- Disconnect the voltage selection plug.
- After the vehicle starts, disconnect the black negative clip - first and store the cable and the clip, then disconnect the red
positive clip + and store the cable and the clip.
7/ POWER FUSE
The booster is equipped with a power fuse. It protects the booster against accidental short circuits on its terminals and against overloads.
To check the fuse, simply press the charge check button. If the blue LED under the fuse lights up, it is in operating condition; if it does
not, it must be changed.
A backup fuse is available on the left hand side of the booster.
Caution: Only use an original BF300A reference fuse.
8/ GUARANTEE
Your FACOM BOOSTER is guaranteed 1 year from its invoice date against all manufacturing flaws.
List of exclusions of guarantee for FACOM BOOSTERS.
- Booster open or which has been disassembled.
- Short-circuit.
- Trace of electric arc on clamps.
- Reversed polarity.
- Continuous use for more than 10 seconds.
- Booster stored discharged.
- Cables and clamps are excluded from the guarantee.
- Booster charged with a charger other than the one supplied with it.
- Trace of shock or impact.
- Fuses.
Booster batteries are wear parts excluded from the guarantee. To increase the lifetime of the batteries, they must be maintained
charged at all times.
Booster chargers are designed to remain connected to mains permanently, and ensure their charge is maintained.
DISPOSAL OF THIS ARTICLE
Dear Customer, If you at some point intend to dispose of this article, then please keep in mind that many of its
components consist of valuable materials, which can be recycled.
Please do not discharge it in the garbage bin, but check with your local council for recycling facilities in your
area.
booster NU-B124.1A_0417.indd 7
7
02/05/2017 09:12:42

Publicité

Table des Matières
loading