To remove the burner base for the Dual Flame and Dual Tier
Ultra Torch burners use a Torx
A
B
C
D
Dual Tier Ultra Burner
A. Inner burner cap
B. Outer burner cap
C. Gas tube opening
D. Burner base
Torch Burner
A. Inner burner cap
B. Inner burner base
C. Outer burner base
D. Burner support
E. Gas tube opening
6. To Convert Standard Burner:
Use 7.0 mm wrench to loosen and remove the orifice
■
spud (A).
Set gas orifice spud aside.
■
Replace with correct Natural gas orifice spud. See
■
Natural gas orifice spud charts.
A
A. Orifice spud
7. To Convert Dual Tier Ultra and Dual Flame Burners:
Use 7.0 mm wrench to loosen and remove the inner
■
orifice spud (A) and the outer orifice spud (B).
Set gas orifice spuds aside.
■
Replace with correct Natural gas orifice spuds. See the
■
Natural gas orifice spud charts.
8
T10 driver to remove the screw.
®
A
B
C
Standard and Dual Flame
A. Burner cap
B. Igniter electrode
C. Burner base
D. Gas tube opening
A
B
C
D
E
A
B
D
Dual Tier Ultra Burner
A. Inner orifice spud
B. Outer orifice spud
8. To Convert Torch Burner
Remove the spring that is shown in the following
■
illustration (C).
Use 7.0 mm wrench to loosen and remove the inner
■
orifice spud (A) and the outer orifice spud (B).
Set gas orifice spuds aside.
■
Replace with correct Natural gas orifice spud. See the
■
Natural gas orifice spud charts.
Return the spring to its original location.
■
C
IMPORTANT: Place Natural gas orifice spuds in plastic
parts bag for future use and keep with package containing
literature.
9. Replace sheet of insulation.
10. Replace burner bases and burner caps.
The igniter electrode is ceramic and could break during
conversion. Be sure that the electrode comes through the
hole in the burner smoothly while you are replacing the
burner base.
A
11. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
12. Plug in cooktop or reconnect power.
REMEMBER: Once you have completed converting all
of the cooktop burners, test the cooktop for leaks by
brushing on an approved noncorrosive leak-detection
solution. If bubbles appear, a leak is indicated. Correct any
leaks found.
13. To adjust single and dual valves, see the "Flame Height
Adjustment" section.
B
Standard and Dual Flame
A. Inner orifice spud
B. Outer orifice spud
A
A. Inner orifice spud
B. Outer orifice spud
C. Spring
B
C
A. Burner cap
B. Electrode
C. Burner base
A
B