Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position. Turn over the spring retainer
so the "NAT" is showing on the bottom. Snap the spring retainer
back into the cap. Reinstall the cap onto the regulator.
E
A. Access cap
B. Gasket
C. Gas pressure regulator
4. If the burner grates are installed, remove them.
Use the following charts to match the correct gas orifice
spud with the burner location and model being converted.
Natural Gas Orifice Spud Chart for Kit W10676661
Burner
Color
Stamp (A)
Rating
5,000 BTU
Green
95
9,100 BTU
White or
130
no color
10,000 BTU
Orange
135
12,00 BTU
Red or
150
Blue
15,000 BTU
Yellow
175
18,00 BTU
Pink
189
17,000 BTU
Inner
Red
175
Outer
Red
57
18,00 BTU
Inner
Brown
180
Outer
Brown
57
19,000 BTU
Inner
White
185
Outer
White
57
Burner Models for Kit W10676661
Model No.
Left
Left
Front
Rear
WCG51US0D
95
175
MGC7430D
Green
Yellow
ICS500DS00
WCG75US0D
95
189
MGC9530D
Green
Pink
WCG97US09
130
135
KCGS350E
No
Orange
ICS655DS00
color
WCG51US6D
130
130
MGC7536D
White
White
WCG97US6D
130
130
MGC9536D
No
No
color
color
KCGS356E
130
130
No
No
color
color
A
B
D
C
D. NAT position
E. LP position
Size
0.95 mm
1.30 mm
1.35 mm
1.50 mm
1.75 mm
1.89 mm
1.75 mm
0.57 mm
1.80 mm
0.57 mm
1.85 mm
0.57 mm
A. Size stamp
Center
Center
Right
Right
Inner
Outer
Rear
Front
Inner
N/A
N/A
150
130
Red
White
N/A
N/A
150
130
Red
White
175
175
95
130
Red
Red
Green
No
color
175
175
95
150
Yellow
Yellow
Green
Red
180
57
95
150
Brown
Brown
Green
Blue
185
57
95
150
White
White
Green
Blue
Natural Gas Orifice Spud Chart for Kit W10676662
Burner
Rating
6,000 BTU
7,000 BTU
10,000 BTU
12,00 BTU
17,000 BTU
Inner
Other
18,000
Inner
Outer
20,000 BTU
Inner
Outer
10,000 BTU
Inner
Outer
Burner Models for Kit W10676662
Model No.
Left
Front
KCGS550E
140
White
KCGS556E
140
White
KCGS950ES
140
White
KCGS956ES
150
Brown
Burner locations
A
A
A. Left front
B. Left rear
C. Center
Right
5. Remove all burner caps and burner bases (see the User
Front
Guide for burner reference).
Outer
130
White
130
White
130
No
color
150
Red
150
Blue
150
Blue
Color
Stamp (A)
Size
Red
105
1.05 mm
Black
115
1.15 mm
White
140
1.40 mm
Brown
150
1.50 mm
Blue
91
0.91 mm
Green
160
1.60 mm
Blue
91
0.91 mm
Blue
165
1.65 mm
Blue
91
0.91 mm
Light Blue
180
1.80 mm
Pink
66
0.66 mm
Pink
123
1.23 mm
Left
Center
Center
Rear
Inner
Outer
105
91
160
Red
Blue
Green
105
91
180
Red
Blue
Light
Blue
105
91
160
Red
Blue
Green
105
91
180
Red
Blue
Light
Blue
B
C
D. Right rear
E. Right front
A
A. Size stamp
Right
Right
Right
Rear
Front
Front
Inner
Outer
115
140
N/A
Black
White
115
140
N/A
Black
white
115
66
123
Black
Pink
Pink
115
66
123
Black
Pink
Pink
D
E
7

Publicité

loading

Ce manuel est également adapté pour:

Torx mgc serieTorx kcgs serieTorx ics5/6 serie